Digital communicator JA-65X 

6/7 

MFM53103 

 

 

5.1 

Internal structure of Contact ID protocol 

The data in the CID protocol has following standardized 

structure: 

 

    XXXX 18 Q XYZ 01 CCC 

 

where 

XXXX

 is the account code of the installation, 

18

 

is the code identification (identical for all events), 

Q

 is a 

number from 1 to  3, 

XYZ

 is the event number, 

01

 is the 

subsystem number, 

CCC

 event source details (see the 

table below). 

 

JA-63/65 

event no. 

 

Q XYZ 

 

Event description 

possible source in JA-

63 or JA-65 

C  S  c  A  J  L  d 

058 

1 110 

Fire alarm 

  4 

 

  4   

 

113 

3 110 

Fire alarm end  

  4 

 

  4   

 

177 

1 120 

Panic alarm  

4   

 

 

  4 

058 

1 120 

Panic alarm from a detector  

  4 

 

 

 

 

 

197 

1 120 

Panic alarm in the subsystem  

 

 

 

  4   

 

187 

3 120 

End of the panic alarm 

4   

 

 

  4 

113 

3 120 

End of the panic alarm from a detector  

  4 

 

 

 

 

 

198 

3 120 

End of the subsystem panic alarm 

 

 

 

  4   

 

058 

1 130 

Intruder alarm in an instant zone 

  4 

 

 

 

 

 

113 

3 130 

End of the intruder alarm in an instant zone 

  4 

 

 

 

 

 

058 

1 134 

Intruder alarm in a delayed zone 

  4 

 

 

 

 

 

113 

3 134 

End of the intruder alarm in a delayed zone 

  4 

 

 

 

 

 

075 

1 137 

System tamper alarm 

4   

4  4  4    4 

129 

3 137 

All system tampers OK 

4   

4  4  4    4 

074 

1 138 

Wrong access code alarm 

4   

 

  4  4 

175 

3 138 

End of a wrong access code alarm 

4   

 

  4  4 

053 

1 140 

Alarm after powering of the control panel 

4   

 

 

 

 

 

075 

1 144 

Detector tamper alarm 

  4 

 

 

 

 

 

129 

3 144 

All detector tampers OK 

  4 

 

 

 

 

 

094 

1 300 

Failure (blown fuse in control panel or other  general failure) 

4   

4  4  4  4  4 

052 

3 300 

Control panel powering 

4   

 

 

 

 

 

148 

3 300 

No failure in the system 

4   

4  4  4  4  4 

172 

1 301 

AC failure 

4   

 

 

 

 

 

173 

3 301 

AC switched on 

4   

 

 

 

 

 

054 

1 302 

Problem with power in an item  

 

 

4  4  4   

 

056 

1 302 

Back up battery failure in the control panel 

4   

 

 

 

 

 

057 

3 302 

End of the back up battery failure  

4   

 

 

 

 

 

055 

3 302 

End of the problem with power in the item 

 

 

4  4  4   

 

051 

1 305 

Reset  

4

 

 

 

 

  4   

049 

1 306 

Entering of programming or user mode  

4

 

 

 

 

  4

 

050 

3 306 

End of programming or user mode 

4

 

 

 

 

  4

 

058 

1 330 

Subsystem alarm 

 

 

 

  4   

 

167 

1 354 

Tel. line failure  

 

 

 

 

  4

 

 

169 

1 354 

Failure of communication in the digital bus 

 

 

 

 

  4   

168 

3 354 

End of tel. line failure 

 

 

 

 

  4

 

 

170 

3 354 

End of a communication failure in the digital bus 

 

 

 

 

  4   

174 

1 355 

RF jamming 

4   

 

 

 

 

 

176 

3 355 

End of RF jamming 

4   

 

 

 

 

 

094 

1 380 

Detector failure 

  4 

 

 

 

 

 

148 

3 380 

End of all detector failures   

  4 

 

 

 

 

 

094 

1 381 

Wireless item communication lost 

  4

 

4  4  4

 

 

 

148 

3 381 

Wireless item communication reestablished 

  4

 

4  4  4

 

 

 

054 

1 384 

Detector power problem 

  4

 

 

 

 

 

 

 

055 

3 384 

End of the detector power problem 

 

 

 

 

 

 

 

026 

1 401 

Disarming  

4

 

 

 

 

  4

 

001 

3 401 

Complete arming  

4

 

 

 

 

  4

 

024 

3 402 

Partial (Home) arming 

4

 

 

 

 

  4

 

025 

3 408 

No code arming 

4

 

 

 

 

  4

 

171 

1 602 

Monitoring station communication testing (in 24 hr.) 

 

 

 

 

  4   

 

Event sources specification in the Contact ID protocol: 

JA-63/JA-65 source 

mark 

code CCC 

Wireless sensor 

001 to 016 

Sensor 

 

201 to 216 

Controller 

401 to 408 

User code 

 

501 to514 

Control panel 

701 

Wireless siren 

711 

Sub control panel 

721 

Tel. Line 

731 

Digital bus 

741 

Summary of Contents for JA-65X

Page 1: ...will disengage all other devices hooked up to the phone line It will then one by one call all programmed numbers and play the user recorded message which corresponds to the event If the dialer makes...

Page 2: ...g method setting is also valid for Central monitoring station communications Factory default tone dialing 2 6 Telephone line checking sequence 9 9 x If this function is enabled the dialer will check r...

Page 3: ...s the connection is established All events are reported to the Monitoring Station in the same order as they happened Once communication has started it can not be interrupted unless the control panel i...

Page 4: ...tting sequence 04 If a dialer is triggered it attempts to make a connection alternating between the primary and the backup telephone number If it is not possible to make a connection after 8 attempts...

Page 5: ...rc 061 Zone alarm 4 rc 062 Zone alarm 5 rc 063 Zone alarm 6 rc 064 Zone alarm 7 rc 065 Zone alarm 8 rc 066 Zone alarm 9 rc 067 Zone alarm 10 rc 068 Zone alarm 11 rc 069 Zone alarm 12 rc 070 Zone alar...

Page 6: ...own fuse in control panel or other general failure 4 4 4 4 4 4 052 3 300 Control panel powering 4 148 3 300 No failure in the system 4 4 4 4 4 4 172 1 301 AC failure 4 173 3 301 AC switched on 4 054 1...

Page 7: ...e programmed in the control panel 8 digits optional bypassing of answering machine if this option was programmed in the control panel if the connection can not be established try to enter space after...

Reviews: