background image

JA-60IR Wireless optical barrier 

MEB52803 

 

instant

delay

 

Figure: 2 The 

JA

-

60N transmitter

 

6.  Then power up the TX unit (red mark) by connecting its battery.   

 

7.  Press the SYNC TEST button in the TX unit (red mark). The 

LED indicator will start flashing to confirm correct positioning of 

the sync beam, if not it is necessary to adjust the relative 

position of the bars. 

 

8.  To test the 3 remaining beams set the DIP switch in the RX unit 

to B2 and press the BEAM TEST button. The LED indicator 

must be flashing while the button is being pressed, otherwise 

adjust the position of the beam B2. Repeat the procedure for 

beams B3 and B4.  

 

9.  Using the AL DIP switch, set whether the alarm will be triggered 

by the interruption of one beam (position 1 –  standard false 

alarm immunity) or two beams (position 2 – higher false alarm 

immunity). 

 

10.  Test radio communication between the detector and the 

receiving unit by briefly pressing (0.1 sec) the TEST-AL button 

which will trigger the detector. To deactivate the detector press 

the TEST-AL button again for about 1 second.  

 

11.  For correct functioning of the tamper positioned in the bars, 

check that the ANTI-STRAPO jumper (see Figure 3) is in the 

OFF position. A tamper of the RX unit is reported to the system 

as a tamper alarm and a tamper of the TX unit is reported as 

activation of the detector (instant or delay zone).  

Note: A tamper alarm is activated 1 second after triggering the tamper 

switch and it is terminated 10 seconds after its deactivation (during these 

10 seconds any other possible activation of the tamper is ignored).   

 

12.  Test the function of the detector by interrupting the beams (for 

example by stepping between the bars). The speed of the 

reaction depends on the number of interrupted beams. After 

activation of the detector, the JA-60N transmitter will add an 

approximately 1 second delay before the signal is sent to the 

receiving unit. 

Battery testing and replacement  

The detector automatically checks the condition of its batteries. If it is 

necessary to replace the batteries, the detector will inform the control 

panel about it. If  a low battery is indicated the detector works as 

normal but, batteries should be replaced as soon as possible (within 

a week). 

Before replacing the batteries, the control panel must be switched 

into mode, which allows detectors opening (User mode or 

Programming mode). 

 

Note:

 Dispose of batteries safely depending on the type of the batteries and 

local  regulation.  Although  this  product  does  not  contain  any  harmful 

materials we suggest you to return the product to the dealer or directly to 

the producer after usage

 

Maintenance  

No special maintenance is needed. The plastic cover can be cleaned 

carefully to avoid any mechanical damage by non-abrasive materials. 

We recommend regular testing of the JA-60IR along with other 

components of the system. 

 

Note:

 Although this product does not contain any harmful material we 

suggest you to return the product to the dealer or directly to the 

producer after usage.

 

 

 

 

RANGE

LOW

HIGH

TEST 

Test 

B2

Test 

B3

Test 

B4

ONE

TWO

BEAM

 INTERRUPTION

TEST - AL

BEAM TEST B2-B4

BATTERY

RX

unit

white mark

RANGE

LOW

HIGH

TAMPER

TEST - AL

SYNC TEST

BATTERY

TX

unit

red mark

TAMPER

TAMPER

TX

bar

red mark

Leave in

position OFF

ANTI-STRAPO

Leave in 

OPTO posit.

A

L

2

1

SYNC

 

Figure 3  