background image

JA-60IR Wireless optical barrier 

MEB52803 

 

The JA-60IR wireless optical barrier 

 

The JA-60IR optical infrared barrier is designed to protect areas 

such as doors, windows, balconies etc. within a range of 5 meters. 

The detector consists of two electronic units and two IR bars. The IR 

bars consist of an IR transmitter (TX) and an IR receiver (RX) 

respectively with four infrared beams built-in, protecting the area 

between them. A JA-60N transmitter is implemented in the RX part 

for wireless communication with Jablotron systems series JA-6x, 

receivers  UC-216,  260 etc. The electronic units can be placed 

directly on the bars or they can be placed separately (e.g. inside the 

house).  

Specification   

IR barrier specification 

Working range: 

0.5m to 5 m 

Number of the beams: 

4 (3 + 1 Sync) 

Detection time: 

1 / 0.5 / 0.35 or 0.2 s 

 

(according to the number of interrupted beams) 

Optical ray  

±10°at 

λ = 900 nm

 

Solar immunity  

≥ 30 000 Lux at ± 5° 

 

Power supply: 

2 x lithium battery 3.6 V / 19 Ah

 

 

type ER 34615H 

 

Battery lifetime: 

typically 3 year (activation 2 times a day)  

Security grade 

2 low to medium risk (EN 50131-1) 

Environment class: 

IV. Outdoo

r general –

25 to +60

 °C (EN 50131-1) 

 

Dimensions 

 

Electronic box:

 

40 x 40 x 240 mm

 

IR bar: 

25 x 25 x 1000 mm

 

JA-60N specification 

Frequency: 

433.92 MHz           

 

Can be operated according to CEPT/ERC REC 70-03 

Working range: 

up to 100 m open area 

Package contents: 2 

x

 IR bars (RX and TX), 2 

x electronic units, 2

 

connecting cables, a built-

in and connected JA

-

60N transmitter

 

 

JABLOTRON ALARMS a.s. hereby declares that  

the JA-60IR is in a compliance with the relevant Union 

harmonisation legislation: Directives No:  2014/53/EU, 

2014/35/EU, 2014/30/EU, 2011/65/EU.  

 

The original of the conformity assessment can be found at 

www.jablotron.com

 - Section Downloads. 

Installation 

Open the electronic units (the TX unit is identified by a red mark and 

the RX unit by a white mark).  Be careful not to damage the JA-60N 

transmitter which is in the cover of the RX unit. 

The same identification is also used in the IR bars. To open the bars 

simply slide down the top cover. When putting it back be careful not 

to damage the tamper inside the bar. 

The upper seals at the end of the bars are made from rubber and are 

only used if the electronic units are not placed directly on the bars. 

The lower seals are made from plastic with holes. 

 

1.  Choose the appropriate position to place both bars just opposite 

each other and within a distance of 5 meters. Drill the holes on 

the bottom parts of each bar and fix them using screws (the 

connector inside the bars must point up). If necessary, it is 

possible to make the bars shorter (being careful not to damage 

beams or cabling) and adjust the beams according to the 

specific needs of the application (by loosening the fixing 

screws). 

 

2.  Fix the electronic units onto the desired place. They can be 

placed directly on the top part of the bars or they can be placed 

separately inside the secured premises (then seal the top part 

of the bar by provided rubber padding). In the case of the RX 

unit (white mark) it is also necessary to take into consideration 

that the radio signal from the built-in transmitter should not be 

shielded (by metal objects etc.).    

 

3.  Connect the bars to the correct electronic units (according to the 

red and white marks) using the provided cable.  

 

4.  Based on the distance between the bars, set the RANGE 

jumpers  (see Figure 3) according to the following table: 

 

Range 

RX (white mark) 

TX (red mark) 

0.5 to 1.5 m 

LOW 

LOW 

1.5 to 3 m 

HIGH 

LOW 

More than 3 m 

HIGH 

HIGH 

This setting also influences the bat

tery  lifetime.  If  the  HIGH 

option is set, then the consumption of the detector will be 

slightly higher. But on the other hand it will increase immunity to 

false alarms, especially during intense daylight.  

 

TX 

IR transmitter 

unit

RX 

IR receiver

unit

+

+

Always install the batteries

with + pole to the top

(as is shown on the picture)

Tx unit

red mark

Tx bar

Red mark

Rx unit

white mark

SYNC

Leave in

OPTO posit.

Rx bar

White mark

fixation

screws

instant

delay

Figure 1 

 

5.  To enroll the barrier to a Jablotron alarm system insert its 

battery into the RX unit (white mark) while the receiver  

(JA-63KR, UC-260 etc) is in enrollment mode (see also the 

installation manual of the receiving unit).  Set the reaction of the 

barrier by DIP switch number 1 on the JA-60N transmitter (see 

Figure 2): 

Position ON = Instant reaction 

Position 1    = delay reaction 

Note: DIP switch number 2 has no influence on the function.  

 