Figure: 2 The
JA
-
60N transmitter
6. Then power up the TX unit (red mark) by connecting its battery.
7. Press the SYNC TEST button in the TX unit (red mark). The
LED indicator will start flashing to confirm correct positioning of
the sync beam, if not it is necessary to adjust the relative
position of the bars.
8. To test the 3 remaining beams set the DIP switch in the RX unit
to B2 and press the BEAM TEST button. The LED indicator
must be flashing while the button is being pressed, otherwise
adjust the position of the beam B2. Repeat the procedure for
beams B3 and B4.
9. Using the AL DIP switch, set whether the alarm will be triggered
by the interruption of one beam (position 1 – standard false
alarm immunity) or two beams (position 2 – higher false alarm
immunity).
10. Test radio communication between the detector and the
receiving unit by briefly pressing (0.1 sec) the TEST-AL button
which will trigger the detector. To deactivate the detector press
the TEST-AL button again for about 1 second.
11. For correct functioning of the tamper positioned in the bars,
check that the ANTI-STRAPO jumper (see Figure 3) is in the
OFF position. A tamper of the RX unit is reported to the system
as a tamper alarm and a tamper of the TX unit is reported as
activation of the detector (instant or delay zone).
Note: A tamper alarm is activated 1 second after triggering the tamper
switch and it is terminated 10 seconds after its deactivation (during these
10 seconds any other possible activation of the tamper is ignored).
12. Test the function of the detector by interrupting the beams (for
example by stepping between the bars). The speed of the
reaction depends on the number of interrupted beams. After
activation of the detector, the JA-60N transmitter will add an
approximately 1 second delay before the signal is sent to the
receiving unit.
Battery testing and replacement
The detector automatically checks the condition of its batteries. If it is
necessary to replace the batteries, the detector will inform the control
panel about it. If a low battery is indicated the detector works as
normal but, batteries should be replaced as soon as possible (within
a week).
Before replacing the batteries, the control panel must be switched
into mode, which allows detectors opening (User mode or
Programming mode).
Note:
Dispose of batteries safely depending on the type of the batteries and
local regulation. Although this product does not contain any harmful
materials we suggest you to return the product to the dealer or directly to
the producer after usage
Maintenance
No special maintenance is needed. The plastic cover can be cleaned
carefully to avoid any mechanical damage by non-abrasive materials.
We recommend regular testing of the JA-60IR along with other
components of the system.
Note:
Although this product does not contain any harmful material we
suggest you to return the product to the dealer or directly to the
producer after usage.
RANGE
LOW
HIGH
TEST
Test
B2
Test
B3
Test
B4
ONE
TWO
BEAM
INTERRUPTION
TEST - AL
BEAM TEST B2-B4
BATTERY
RX
unit
white mark
RANGE
LOW
HIGH
TAMPER
TEST - AL
SYNC TEST
BATTERY
TX
unit
red mark
TAMPER
TAMPER
TX
bar
red mark
Leave in
position OFF
ANTI-STRAPO
Leave in
OPTO posit.
A
L
2
1
SYNC
Figure 3