20

2.3.4   OPERATING THE SYSTEM USING SMS COMMANDS

SMS commands can control individual sections and programmable outputs 

just like keypad segment buttons. The form of text message to operate  
the system is: CODE_COMMAND. The actual commands are predefined (SET/
UNSET) with an additional numeric parameter which identifies a specific section.

One SMS can control multiple sections at the same time. In this case, added 

numbers in the command define sections.

Example of an SMS command used to set sections 2 and 4.

CODE_SET_2_4

The commands to control the programmable outputs can be programmed 

by a system installer. For example, you may choose BLINDS DOWN as your 
command to close the blinds on your windows. It is also possible to configure  
the system not to require a code before a command. In such case the command is simply automatically 
identified when the system recognizes the user’s phone number from which the SMS was sent.  
Configuration is done by a service technician.

2.3.5   OPERATING THE SYSTEM REMOTELY USING A COMPUTER (J-LINK)

The JABLOTRON 100+ system can be operated remotely using a computer 

with an installed J-Link software.

It can be downloaded from the “Downloads” section  

of the www.jablotron.com website or it can be found in the control panel’s  
SD card. The registration code of the security system (a 15-digit code) and  
the telephone number of its SIM card is required to connect to the system 
remotely the first time. Remote access is initiated by clicking on “Internet”  
in the main menu.

After establishing the connection with the control panel, the operating  

is the same as when connecter locally via USB cable.

2.3.6   CONTROLLING THE PROGRAMMABLE OUTPUTS (PG)
2.3.6.1   KEYPAD SEGMENT

A PG output switches on by pressing the right button of the segment and switches off by pressing  

the left button. If the output is configured as a pulse output, it is switched off according to the pre-set time.

PG control may or may not be stored in the control panel’s event memory. Configuration is done  

by a service technician.

Authorization is/is not demanded based on the system configuration.

2.3.6.2   USER KEYPAD AUTHORIZATION

It is possible to activate a PG output just by user authorization (entering a code or using an RIFD tag).  

The PG output must be configured to activate from a designated keypad.

2.3.6.3   FROM THE MENU OF THE KEYPAD WITH AN LCD DISPLAY

After user authorization the programmable outputs can be controlled from  

the menu of the keypad with an LCD display. The user has access  
to programmable outputs depending on the user’s permissions.
Control from the keypad menu

a

  Authorization by a valid code or an RFID chip.

a

  Enter the menu by pressing ENTER.

a

  PG Control 

 ENTER.

a

  Select the desired PG group using arrows (1–32), (33–64), (65–96),  

     (97–128) 

 ENTER.

2.   OPERATING THE JABLOTRON 100+ SYSTEM

Summary of Contents for 100+

Page 1: ...User manual...

Page 2: ...COMPUTER J LINK 18 2 3 REMOTE OPERATING 18 2 3 1 OPERATING THE SYSTEM USING THE MyJABLOTRON SMARTPHONE APP 19 2 3 2 OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE 19 2 3 3 OPERATING THE SYSTE...

Page 3: ...5 1 USING THE LCD KEYPAD 23 5 2 USING THE J LINK SOFTWARE AND A COMPUTER 23 5 3 LOGGING INTO MyJABLOTRON WEB SMARTPHONE 23 6 PERIODICAL MAINTENANCE 24 7 TECHNICAL SPECIFICATIONS 25 8 GLOSSARY OF TERMS...

Page 4: ...ed alarm stop sirens from sounding just by authorization in any part of the system depending on their access rights However that does not automatically unset the system unless the system s default set...

Page 5: ...is allowed only to set a designated section and is allowed to control ON OFF PG outputs which require authorization Users with this level of authorization are not allowed to change their code and are...

Page 6: ...s are clearly labelled and coloured using traffic light logic so that each segment status is distinctly indicated A segment can also be used to indicate a status e g opened garage door or to control v...

Page 7: ...by entering a code or the contactless method RFID card tag or a combination of both for higher security Keypad with an LCD display and a card reader the user can control the system using segments and...

Page 8: ...isplay the J Link software or MyJABLOTRON app If the Code with a prefix parameter is enabled the users can be allowed to change their code If the Code with a prefix parameter is disabled the codes can...

Page 9: ...and according to the internal settings Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control p...

Page 10: ...Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section where the entrance delay has been triggered Consult the installation wit...

Page 11: ...ssed a second time it flashes red If the system is partially set indicated by a continuous yellow light the entire system can be fully set by authorization and pressing the yellow button Once the butt...

Page 12: ...in menu from the keypad with an LCD display Cancel warning indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 5013...

Page 13: ...EEN Unset a YELLOW Partially Unset a RED Set Authorization can be done by entering an access code on the keypad or using an RFID card tag assigned to a particular user Each user can have one code and...

Page 14: ...s Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control panel configuration Displays a list of...

Page 15: ...ay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator flashing yellow reported to the ARC and indicated by an external siren applies to the sec...

Page 16: ...when somebody moves inside the section 1 When you enter the building triggering a detector with a Delayed zone reaction the system starts indicating an entrance delay with a continuous tone the system...

Page 17: ...function button rapidly flashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly flashing red function button indicates the alarm...

Page 18: ...ns The closed lock icon sets programmed sections the opened lock icon unsets them Correct command execution is confirmed by an LED light unsetting green setting red A communication fault out of the co...

Page 19: ...then it is possible to set unset the system in the J Link software using an on screen virtual keypad click on Keypad in the main menu WARNING When the system is controlled via PC it doesn t check for...

Page 20: ...s and Gallery The bottom of the home page has an overview of the most recent system events MyJABLOTRON offers free notifications SMS e mail or push notifications for selected system section events pro...

Page 21: ...curity system a 15 digit code and the telephone number of its SIM card is required to connect to the system remotely the first time Remote access is initiated by clicking on Internet in the main menu...

Page 22: ...code or card tag will no longer be accepted by the system The users will also not receive any SMS alerts or voice reports to their phone Only the system administrator or service technician can block...

Page 23: ...t to flash by pressing Enter Then the RFID card tag must be placed on to the reader or the serial number must be manually entered After confirming by pressing Enter again the RFID card tag is added To...

Page 24: ...ol panel Each entry includes the date time start and end and source cause origin of the event The different ways of browsing through the system s event history 5 1 USING THE LCD KEYPAD Accessing the e...

Page 25: ...ted with a selection of sections where the maintenance is needed In the maintenance mode no alarms will be triggered in the selected sections including opening or removing the detectors from the insta...

Page 26: ...ply unit Type A according to EN 50131 6 GSM communicator 850 900 1800 1900 MHz GSM communicator 3G 850 900 1800 1900 2100 MHz Classification Security grade 2 Environmental class II according to EN 501...

Page 27: ...ly functioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Out...

Page 28: ...27 9 NOTES...

Page 29: ...28 9 NOTES For questions and further information contact your installer MMD55300...

Page 30: ...M ENJA100 USER www jablotron com...

Reviews: