2.1.2.3   DURESS ACCESS CONTROL

This function provides unsetting of the system in a special mode. The system seemingly unsets, however 

it triggers a silent panic alarm, which is then reported to selected users (including ARC).

Unsetting under duress is executed by adding 1 to the last number in a valid code.

Example for a code with the prefix:

Valid code: 2*9999 

 

 

Code for unsetting under duress: 2*9990

Example for a code without the prefix: 

Valid code: 9999 

 

 

Code for unsetting under duress: 9990

2.1.2.4   PARTIAL ALARM SETTING 

The system can also be configured to be partially set which allows guarding only by certain detectors  

in a section. 

Example: At night, it is possible to set the door and window detectors only, while motion detectors inside  

a house do not react to anything.

To fully set the premises in which partial setting is enabled, the button to set the system has to be pressed 

twice. After the button is pressed once it flashes yellow, when it is pressed a second time it flashes red.

If the system is partially set – indicated by a continuous yellow light – the entire system can be fully set  

by authorization and pressing the yellow button. Once the button is pressed, the system will be fully set and  
the button turns red.

2.1.2.5   TERMINATING A TRIGGERED ALARM 

1.  Authorize yourself using

the keypad 

(enter a code or hold 

a card or a tag up to the reader). 
The green backlit indication button 
will start flashing.

2.  Press the right segment button 

of the selected section.

3.  The command is executed, 

and the segment button turns 
yellow to indicate a partially set 
section.

 

2.   OPERATING THE JABLOTRON 100+ SYSTEM

1.  Authorize yourself 

using the keypad (enter 
a code, hold a tag  
up to the reader).

2. Press 

the left 

segment button  
of the section where 
the alarm has been 
triggered.

3.  Unsetting is finished

and sirens are silenced. 
The green flashing 
button indicates  
unsetting of the parti-
cular section. The red 
flashing light indicates 
alarm memory.

4.  Authorize yourself

and press the green 
button again to cancel 
the alarm memory 
indication.

5.  The segment indica-

tes the unset section 

with a continuously lit 
up green button.

Summary of Contents for 100+

Page 1: ...User manual...

Page 2: ...COMPUTER J LINK 18 2 3 REMOTE OPERATING 18 2 3 1 OPERATING THE SYSTEM USING THE MyJABLOTRON SMARTPHONE APP 19 2 3 2 OPERATING THE SYSTEM VIA THE MyJABLOTRON WEB INTERFACE 19 2 3 3 OPERATING THE SYSTE...

Page 3: ...5 1 USING THE LCD KEYPAD 23 5 2 USING THE J LINK SOFTWARE AND A COMPUTER 23 5 3 LOGGING INTO MyJABLOTRON WEB SMARTPHONE 23 6 PERIODICAL MAINTENANCE 24 7 TECHNICAL SPECIFICATIONS 25 8 GLOSSARY OF TERMS...

Page 4: ...ed alarm stop sirens from sounding just by authorization in any part of the system depending on their access rights However that does not automatically unset the system unless the system s default set...

Page 5: ...is allowed only to set a designated section and is allowed to control ON OFF PG outputs which require authorization Users with this level of authorization are not allowed to change their code and are...

Page 6: ...s are clearly labelled and coloured using traffic light logic so that each segment status is distinctly indicated A segment can also be used to indicate a status e g opened garage door or to control v...

Page 7: ...by entering a code or the contactless method RFID card tag or a combination of both for higher security Keypad with an LCD display and a card reader the user can control the system using segments and...

Page 8: ...isplay the J Link software or MyJABLOTRON app If the Code with a prefix parameter is enabled the users can be allowed to change their code If the Code with a prefix parameter is disabled the codes can...

Page 9: ...and according to the internal settings Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control p...

Page 10: ...Unset section by authorization only during entrance delay parameter is enabled then mere authorization will unset such section where the entrance delay has been triggered Consult the installation wit...

Page 11: ...ssed a second time it flashes red If the system is partially set indicated by a continuous yellow light the entire system can be fully set by authorization and pressing the yellow button Once the butt...

Page 12: ...in menu from the keypad with an LCD display Cancel warning indication Indication of a triggered tamper alarm can be terminated only by a Service technician or Administrator Note When using the EN 5013...

Page 13: ...EEN Unset a YELLOW Partially Unset a RED Set Authorization can be done by entering an access code on the keypad or using an RFID card tag assigned to a particular user Each user can have one code and...

Page 14: ...s Displays a detailed list of the event memory Shows a list of triggered detectors preventing setting the system provided this option is activated in the control panel configuration Displays a list of...

Page 15: ...ay has expired then the control panel will unset again Unsuccessful setting is indicated by a system indicator flashing yellow reported to the ARC and indicated by an external siren applies to the sec...

Page 16: ...when somebody moves inside the section 1 When you enter the building triggering a detector with a Delayed zone reaction the system starts indicating an entrance delay with a continuous tone the system...

Page 17: ...function button rapidly flashing red You need to authorize yourself using the keypad in order to terminate the alarm The section remains set a rapidly flashing red function button indicates the alarm...

Page 18: ...ns The closed lock icon sets programmed sections the opened lock icon unsets them Correct command execution is confirmed by an LED light unsetting green setting red A communication fault out of the co...

Page 19: ...then it is possible to set unset the system in the J Link software using an on screen virtual keypad click on Keypad in the main menu WARNING When the system is controlled via PC it doesn t check for...

Page 20: ...s and Gallery The bottom of the home page has an overview of the most recent system events MyJABLOTRON offers free notifications SMS e mail or push notifications for selected system section events pro...

Page 21: ...curity system a 15 digit code and the telephone number of its SIM card is required to connect to the system remotely the first time Remote access is initiated by clicking on Internet in the main menu...

Page 22: ...code or card tag will no longer be accepted by the system The users will also not receive any SMS alerts or voice reports to their phone Only the system administrator or service technician can block...

Page 23: ...t to flash by pressing Enter Then the RFID card tag must be placed on to the reader or the serial number must be manually entered After confirming by pressing Enter again the RFID card tag is added To...

Page 24: ...ol panel Each entry includes the date time start and end and source cause origin of the event The different ways of browsing through the system s event history 5 1 USING THE LCD KEYPAD Accessing the e...

Page 25: ...ted with a selection of sections where the maintenance is needed In the maintenance mode no alarms will be triggered in the selected sections including opening or removing the detectors from the insta...

Page 26: ...ply unit Type A according to EN 50131 6 GSM communicator 850 900 1800 1900 MHz GSM communicator 3G 850 900 1800 1900 2100 MHz Classification Security grade 2 Environmental class II according to EN 501...

Page 27: ...ly functioning parts called sections Each section can have its assigned detectors keypads as well as sirens users and their telephone numbers There can be up to 15 sections per system Programmable Out...

Page 28: ...27 9 NOTES...

Page 29: ...28 9 NOTES For questions and further information contact your installer MMD55300...

Page 30: ...M ENJA100 USER www jablotron com...

Reviews: