background image

 

External document 

File name: 

EYE-02 Wireless peripherals 

11/12 

URL: 

http://www.jablocom.com/download 

 

Repeat the reset procedure with button of the second relay (Y) 

2.  Enroll the camera into relay X or Y. Repeatedly press the relevant X or Y button until 4 LED lights flash.  
3.  Send the enrolment signal from the camera 

 

Go to JabloTool via internet, tab Peripherals and click on Add new device. Other options are described 
in the chapter 4.1.1., step 3. 

Relay will now respond to wireless instructions of camera switches. If you enrolled the camera into the first relay 
switch (X), the relay will be controlled by camera switch DeviceX. If you enrolled the camera into second relay 
switch (Y), the relay will respond to instructions of the camera switch DeviceY. 

 

5.2.3 

Enrolling AC-83 

1.  First reset the relay. You can skip this step if no other device is enrolled there. 

 

Undo the cover and repeatedly press the button of the first relay switch (X) to achieve several LED 
flashes 

 

Continuously press the same button and keep pressing it (for approx. 4 seconds) until all the LEDs 
flash a couple of times (= reset). Then release the button. 

 

Repeat the reset procedure with button of the second relay switch (Y) 

2.  Enroll the camera into the relay X or Y. Use the X or Y button depending on to which relay you want to 

enroll the camera. Enter enrollment mode of relay (this is indicated by red LED No. 2 or 4 flashing) by 
pressing its button X or Y. 

3.  Send the enrollment signal from the camera 

 

Go to JabloTool via internet, tab Peripherals and click on Add new device. Other options are described 
in the chapter 4.1.1., step 3. 

  

T

HERMOSTATS

 

Thermostats control temperature in heated premises. They control a relay and automatically switch it ON or OFF. If 
temperature in the room is lower than set temperature, the thermostat sends switches the relay ON. The relay 
makes contact and the heating turns ON. 

Camera can be enrolled into relay where thermostat is enrolled. Camera then works as a central switch. If camera 
switched the relay OFF, the relay will only make contact when the temperature decreases below the economical 
temperature. If camera switches the relay ON, the relay will always follow the command from thermostat. To work 
like this, the relay needs to be enrolled in the camera and thermostat needs to be enrolled in the relay. 

Thermostat can be also enrolled directly to the camera. Thermostat will then report to the camera 

 

when battery in the thermostat is flat 

 

when temperature decreases below preset level (event Panic Alarm is generated in the camera); this can 
indicate that heating system has stopped working or there may be danger that heating system will freeze. 

 

when temperature exceeds 60

°C (event Fire Alarm is generated in the camera) 

 

More thermostats can be enrolled into one wireless relay. Heating is then turned ON if at least one thermostat 
requires this. 

 

Wireless thermostat TP-82 
Programmable wireless indoor thermostat TP-83 

TP-82 and TP-83 measure and set temperature that should be maintained in a room. Temperature 
adjustment is performed by turning the setting knob. Thermostats are enrolled into relay modules 
AC-82, UC-82, AC-83 or wireless socket AC-88. These relays then control the heating according to 
thermostat commands. The relays can be  then also enrolled into the camera so they can be 
remotely turned ON and OFF by the camera. 

TP-83 has a programmable weekly heating schedule. It is capable of recognizing warm-up 
persistence characteristics (within 2 days) and it will adjust the settings accordingly. You only set at 
what time you wish to achieve the selected temperature and the thermostat will, within 2 days prior 
to this moment, adjust the heating so that the set temperature is achieved. 

 

 

Summary of Contents for EYE-02

Page 1: ...External document File name EYE 02 Wireless peripherals 1 12 Wireless peripherals EYE 02 GSM Security Camera Application note...

Page 2: ...d with the camera at the same time Operating range of peripherals is 100m in free space Wireless buttons detectors and sirens are powered by batteries with typical lifetime of at least 2 years Exact b...

Page 3: ...to your camera via www jablotool com o Go to tab Peripherals o Click on Add new device 3 Using JabloTool via USB cable o Click on the icon of camera in the list of on line devices o Go to Configurati...

Page 4: ...doorbell button RC 89 Pressing the button generates Panic alarm even when EYE 02 is in SLEEP mode Example of use The camera is focusing on entrance area in a building Pressing the doorbell button wak...

Page 5: ...the MW detector is activated and confirms activation of the PIR detector After the confirmation the detector reports Alarm to the camera The detector is enrolled as one peripheral into the camera Wire...

Page 6: ...e Detector can be enrolled into wireless internal siren JA 80L that will signalize with melody when windows or doors are open Picture 4 EYE 02 camera used with Magnetic door window opening detector JA...

Page 7: ...R JA 80M JA 80P JA 80PB JA 80S JA 80W JA 81M JA 82M JA 82SH JA 85B JA 85P JA 86P JA 88P Plug the detector JA 80G into the mains Detectors should be at least 1 meter away from the camera during enrolme...

Page 8: ...evices go to Configuration External devices and click on Add new device or Note Do not use remote control to switch the camera in the Enrol mode when siren is in Enroll mode because the remote control...

Page 9: ...the relay OFF Camera switches can be configured to several modes SMS ON OFF Switch will turn ON or OFF after pressing a button in JabloTool or after sending an SMS command Example of use Turning ON or...

Page 10: ...mera it should listen to That is why the camera needs to be enrolled into the relay 5 2 1 Enrolling AC 88 1 First reset the socket You can skip this step if no other device is enrolled there Unplug th...

Page 11: ...er than set temperature the thermostat sends switches the relay ON The relay makes contact and the heating turns ON Camera can be enrolled into relay where thermostat is enrolled Camera then works as...

Page 12: ...6 1 1 Enrolling thermostats into EYE 02 camera 1 Switch the camera into Enroll mode it is described in chapter 1 2 2 Insert battery into the thermostat TP 82 or TP 83 6 1 2 Enrolling thermostats and...

Reviews: