External document
File name:
EYE-02 Wireless peripherals
11/12
URL:
http://www.jablocom.com/download
Repeat the reset procedure with button of the second relay (Y)
2. Enroll the camera into relay X or Y. Repeatedly press the relevant X or Y button until 4 LED lights flash.
3. Send the enrolment signal from the camera
Go to JabloTool via internet, tab Peripherals and click on Add new device. Other options are described
in the chapter 4.1.1., step 3.
Relay will now respond to wireless instructions of camera switches. If you enrolled the camera into the first relay
switch (X), the relay will be controlled by camera switch DeviceX. If you enrolled the camera into second relay
switch (Y), the relay will respond to instructions of the camera switch DeviceY.
5.2.3
Enrolling AC-83
1. First reset the relay. You can skip this step if no other device is enrolled there.
Undo the cover and repeatedly press the button of the first relay switch (X) to achieve several LED
flashes
Continuously press the same button and keep pressing it (for approx. 4 seconds) until all the LEDs
flash a couple of times (= reset). Then release the button.
Repeat the reset procedure with button of the second relay switch (Y)
2. Enroll the camera into the relay X or Y. Use the X or Y button depending on to which relay you want to
enroll the camera. Enter enrollment mode of relay (this is indicated by red LED No. 2 or 4 flashing) by
pressing its button X or Y.
3. Send the enrollment signal from the camera
Go to JabloTool via internet, tab Peripherals and click on Add new device. Other options are described
in the chapter 4.1.1., step 3.
6
T
HERMOSTATS
Thermostats control temperature in heated premises. They control a relay and automatically switch it ON or OFF. If
temperature in the room is lower than set temperature, the thermostat sends switches the relay ON. The relay
makes contact and the heating turns ON.
Camera can be enrolled into relay where thermostat is enrolled. Camera then works as a central switch. If camera
switched the relay OFF, the relay will only make contact when the temperature decreases below the economical
temperature. If camera switches the relay ON, the relay will always follow the command from thermostat. To work
like this, the relay needs to be enrolled in the camera and thermostat needs to be enrolled in the relay.
Thermostat can be also enrolled directly to the camera. Thermostat will then report to the camera
when battery in the thermostat is flat
when temperature decreases below preset level (event Panic Alarm is generated in the camera); this can
indicate that heating system has stopped working or there may be danger that heating system will freeze.
when temperature exceeds 60
°C (event Fire Alarm is generated in the camera)
More thermostats can be enrolled into one wireless relay. Heating is then turned ON if at least one thermostat
requires this.
Wireless thermostat TP-82
Programmable wireless indoor thermostat TP-83
TP-82 and TP-83 measure and set temperature that should be maintained in a room. Temperature
adjustment is performed by turning the setting knob. Thermostats are enrolled into relay modules
AC-82, UC-82, AC-83 or wireless socket AC-88. These relays then control the heating according to
thermostat commands. The relays can be then also enrolled into the camera so they can be
remotely turned ON and OFF by the camera.
TP-83 has a programmable weekly heating schedule. It is capable of recognizing warm-up
persistence characteristics (within 2 days) and it will adjust the settings accordingly. You only set at
what time you wish to achieve the selected temperature and the thermostat will, within 2 days prior
to this moment, adjust the heating so that the set temperature is achieved.