Trouble
Probable Cause
Remedy
Instrument fails to
operate
Circuit breaker open
Check master and avionics
circuit breakers. Re-set if
necessary.
Defective mechanism
Substitute known-good
tachometer and check reading.
Replace instrument
Incorrect indication
Sensor not positioned correctly
Adjust sensor per Engine Manual
Instructions.
Analogue Tacho: Incorrectly set
dip-switches or tachometer
programming.
Check switch positions /
programming as appropriate to
the tachometer. Refer to engine
manuals.
Hand oscillates
Same probable causes as for
“Incorrect Indication” above.
See remedies for “incorrect
indication” above.
Figure 179
– Hall Effect Sensor Wiring (For Tach with Jabiru Logo on Face)