![J.P. Instruments EDM-900 Installation Manual Download Page 30](http://html1.mh-extra.com/html/j-p-instruments/edm-900/edm-900_installation-manual_3102691030.webp)
FAA Approved Installation Manual for the
Report No 908
EDM-900 and EDM-930
Page 30 of 56 Rev I
Primary Engine Data Management System
Date 1-18-2013
29.
EDM-900/930 Specifications and Limitations
The following parameters must be customized for the aircraft into which the EDM-900/930 is installed.
Factory set limits or default values for EDM-900/930
1.
TIT 1650 F
TSO-C43
2.
CHT 450 F
TSO-C43
3.
Oil Temp Low 90 F
TSO-C43
4.
Oil Temp HI 230F
TSO-C43
5.
Oil Press low 15 psi
TSO-47
6.
Oil Press Hi 100 psi
TSO-47
7.
Vacuum 0- 15”hg
TSO-47
8.
RPM 2700 Limit and range
TSO-C49
9.
RPM set to cyl 6
TSO-C49
10. Map 32 In hg HI
TSO-C45
11. Map setting 29.90 In Hg
TSO-C45
12. Fuel Pressure Hi 35 psi Injected
TSO-47
13. Fuel Pressure Lo 15 psi Injected
TSO-47
14. Fuel Pressure Hi 8 psi Carb
TSO-47
15. Fuel Pressure Lo .5 psi Carb
TSO-47
16. Fuel Flow 24 GPH
TSO-C44
17. K-factor 29.99
18. Carburetor filter smoothing 1
19. Ammeter configuration (load or charge-discharge). Load NON TSO
20. HC-120 (% of HP)
NON TSO
21. Fuel Level Resistive/Capacitive
TSO-55
22. Low fuel 10 Gal
23. Low time 45 Min
24. Main tank 75 gallons
25. Aux tank 0
26. GPS set at GARMIN
27. Diff 500 degrees
TSO-C43
28. CLD 60 degrees per minute
TSO-C43
29. Amps limit 100 amps
NON TSO
30. Record time, 6 sec intervals
NON TSO
31. Hobbs on at 1000 RPM
NON TSO
On 14 vdc systems during start-up the EDM may reset it self. This is normal due to extremely low battery voltage.
The conditions and test required for TSO approval of this article are minimum performance standards. It is the
responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine
that the aircraft installation conditions are within the TSO standards. The article may be installed only if installation of
the article is approved by the Administrator. The functions of Volts, Amps, and Horse Power were tested to DO-160D
and DO-178B, but not TSO’d since no TSO exist for these functions. Deviation granted for TSO-C49b to include digital
display and sensor. All TSO required probes, transmitters and sensors also tested to DO-160D.