7.
Tap
TANK
to select the next active tank and repeat previous step. Continue until all tanks ‘points’ have
been set.
8.
Tap
TABLE
. You see ‘
Fuel Table Data
’ ( White at top of screen) with a table. You may change any of the
fuel levels in the left column except for empty. You will enter the readings taken previously on paper into
the right column.
9.
Tap/hold
STEP
to select the cell you want to edit. Tap
EDIT
to change the value. Tap or hold
Modify
to
change digit. Tap digit to change another part of the number.
10. Tap
SAVE
to record it. Follow the on-screen menus to edit the value. Repeat previous step until all tanks
data have been entered.
11. You see ‘
Save fuel tank data?
’. Answer
SAVE
to store all final data values or
CANCEL
to return to table
editing. To complete the process, tap
SAVE
a second time.
25.
Fuel Flow Totalizer, Refuel Question
The fuel flow totalizer can be set to a
different
value than the fuel level
tank size
. To reprogram the “Refuel
setting for Main (total) and Auxiliary (total), enter the “Factory Program Mode” by holding buttons 1 and 2 in for a
few seconds until the display reads “Program”. Keep tapping
next
until you see “
END
”. At this point hold in button