powered by air !
P RO D U C T I N F O R M AT I O N
Page 14
In order to provide adequate compressed air quality,
operation with a service unit is recommended. Usually,
an oiler is not required in the service unit, as the motor
is provided with internal permanent lubrication.
Pressure dew point at least 10° C below the lowest
expected ambient temperature
Do not operate JDN Air Hoists with
other gases.
With moist air and ambient temperatures at or below
0° C, there is a danger of icing in the motor.
Icing can be prevented by:
the use of an upstream air dryer or using a service
unit with oiler,
adding anti-icing agent to the lubrication oil
(depending upon moisture content of compressed air)
or using compressed air oil (Art. no. 11900) with
anti-icing agent for relevant temperatures.
In the event that your JDN Air Hoist is operated in
combination with a trolley, please also read the trolley
operation manual and the relevant accident prevention
regulations for operation with trolleys.