![J. A. Roby FORGERON Instruction Manual Download Page 15](http://html1.mh-extra.com/html/j-a-roby/forgeron/forgeron_instruction-manual_625853015.webp)
15
March 1
st
, 2015
Chimney connector installation.
The chimney connector is a set of single wall or double wall flue
pipes and elbow installed between the stove collar and the
chimney collar. The single wall chimney connector is sold into
any hardware store and are not homologated and certified.
Some rules must be followed to install it and can be found in the
installation codes for wood heater.
•
Double wall chimney connector.
Your J. A. Roby cook stove was design and tested with a
single wall chimney connector but it is possible to install a 6
inches (15.2 cm) double wall certified chimney connector.
To do that you must detach the blank piece on the top
assembly, on the bottom of the facing assembly and on
each decorative side of the warmer.
We recommend to detach the blank pieces before
assembling the cook stove warmer
ATTENTION:
•
For the clearance between combustible materials
and double wall chimney connector, see
manufacturer manual.
•
Single wall chimney connector..
For the single wall chimney connector you must use The
single wall or double wall chimney connector and it must be
6 inches diameter and have a minimum thickness of 24
gauge (0.025 inches 0.64 mm) For the single wall section
and elbow outside the warmer. Install a metal heat shield, 1
inches (25.4 mm) offset.
ATTENTION:
•
If heat shield is not present you must move away
the cook stove to keep 18 inches (45.7 cm)
clearance between combustibles materials and
1 the chimney connector.
•
Any horizontal section must have a 1/4 inches
(6.35 mm) by feet (30 cm) slope toward the
chimney collar.
•
Clearance between roof and horizontal single wall
chimney connector must be 18 inch (45.7 cm) or
more.
•
Clearance between roof and horizontal double
wall chimney connector, follow chimney connector
manufacturer indication
1. Chimney connector assembly installation.
Make a summary installation of all sections and elbows (if
necessary) to ensure that you meet the clearances and
inclinations of the horizontal sections and check that you have
all the necessary parts to final installation.
o
For direct vertical installation you will need.
1 x 24 inches (61 cm) vertical section or more
1 x adequate length of telescopic chimney
connector section allowing you to connect
the last chimney connector section to the
roof support collar.
Note: More section can be used for higher roof.
o
For horizontal run installation you will need
1 x 24 inches (61 cm) vertical section or
more.
1 x 90° elbow or 2 x 45°elbow.
1 x adequate length of telescopic chimney
connector section to a maximum of 36 inches
(91.4 cm)
Note: For better performance two 45 degree elbow, with or
without straight section between the two are preferable.
2. Disassemble the whole thing and start screwing the pieces
from the stove to the roof chimney collar