0x26c01049
BPW_k_INIT_FBC_FAILED
Failed to initialize FBC unit
MINOR
73
1
0x36c0104a
BPW_k_NULL_POINTER_TRACKER
The null pointer tracker has been triggered
FATAL
74
1
0x36c0104b
BPW_k_GEN_FBC_MUTEX_ERROR
FBC mutex API returns unexpected error
FATAL
75
1
0x36c0104c
BPW_k_ERR_FILE_SYSTEM_MOUN
T
This error means that it was not possible to mount a file
system.
FATAL
76
1
0x36c0104d
BPW_k_ERR_FILE_SYSTEM_QUER
Y
This error means that it was not possible get task access
for the file system.
FATAL
77
1
0x36c0104e
BPW_k_ERR_FILE_SYSTEM_INIT
This error means that it was not possible initialize the file
system.
FATAL
78
1
6.5.14 COM_k_UNIT_ID_MC_BPW_PNIO (unit id 109)
Error Code
Define
Description
Error
Class
Unit
Err
File
ID
0x26d01001
DEV_k_INIT_PARAM_INV
This error means that parameters in the init structure are
invalid
MINOR
1
1
0x36d01001
BPWP_k_INIT_TASK_CREATE_FAIL
ED
This error means that an error occurred while creating the
Init task
FATAL
1
1
0x36d02001
ALR_k_OS_SEM_CREATE_FAILED
This error means that an error occurred while creating an
OS semaphore
FATAL
1
2
0x36d03001
CYC_k_OS_SEM_CREATE_FAILED
This error means that an error occurred while creating an
OS semaphore
FATAL
1
3
0xa6d04001
REC_k_READ_RESP_FAILED
This error means that an error occurred while calling
PNIO_rec_read_rsp()
MINOR
1
4
0x26d05001
DEV_k_INIT_PARAM_INV
This error means that parameters in the init structure are
invalid
MINOR
1
5
0x36d01002
DEV_k_NO_MEM_FOR_MOD_LIST
This error means that an error occurred while allocation a
memory for the module list
FATAL
2
1
0xa6d02002
ALR_k_RET_OF_SUB_FAILED
This error means that an error occurred while sending
"RETURN OF SUBMODULE" alarm
MINOR
2
2
0xb6d03002
CYC_k_SEM_PEND_FAILED
This error means that an error occurred while pending on
a semaphore
FATAL
2
3
0xa6d04002
REC_k_WRITE_RESP_FAILED
This error means that an error occurred while calling
PNIO_rec_write_rsp()
MINOR
2
4
0x36d05002
DEV_k_NO_MEM_FOR_MOD_LIST
This error means that an error occurred while allocation a
memory for the module list
FATAL
2
5
0x16d01003
BPWP_k_UNSUPPORTED_REQ
This error means that we got request from the host un-
supported by PROFINET
INFO
3
1
0x36d01003
DEV_k_NO_MEM_FOR_SUBMOD_LI
ST
This error means that an error occurred while allocation a
memory for the submodule list
FATAL
3
1
0x16d02003
ALR_k_ALARM_TYPE_INV
This error means that we got "send alarm" request with
an invalid alarm type spesified
INFO
3
2
0xb6d03003
CYC_k_SEM_POST_FAILED
This error means that an error occurred while posting on
a semaphore
FATAL
3
3
0x36d04003
REC_k_READ_AR_NOT_EXIST
This error means that we got "read record" indication from
the PNIO stack for AR that does not exist in our database
FATAL
3
4
0x36d05003
DEV_k_NO_MEM_FOR_SUBMOD_LI
ST
This error means that an error occurred while allocation a
memory for the submodule list
FATAL
3
5
0x16d01004
BPWP_k_UNSUPPORTED_CONF
This error means that we got a confirmation from the host
unsupported by PROFINET
INFO
4
1
0xa6d01004
DEV_k_DEVICE_OPEN_FAILED
This error means that an error occurred in the "open
device" call sequence (see PNIO last error)
MINOR
4
1
0x26d02004
ALR_k_ALARM_IND_AR_NOT_EXIS
T
This error means that we got "recv alarm" indication from
the PNIO stack for AR that does not exist in our database
MINOR
4
2
0x36d03004
CYC_k_TASK_START_FAILED
This error means that an error occurred while starting the
IO task
FATAL
4
3
0x26d04004
REC_k_READ_SESS_KEY_INV
This error means that we got "read record" indication from
the PNIO stack with an invalid session key
MINOR
4
4
0xa6d05004
DEV_k_DEVICE_OPEN_FAILED
This error means that an error occurred in the "open
device" call sequence (see PNIO last error)
MINOR
4
5
0x26d01005
BPWP_k_VAR_CREATE_API_NOT_
EXIST
This error means that an error occurred while creating a
new variable because the API of this variable does not
exist in our database
MINOR
5
1
0xa6d01005
DEV_k_PNIO_DEV_CLOSE_FAILED
This error means that an error occurred while calling
PNIO_device_close
MINOR
5
1