Configuration
3.1 Overview of the parameters
Type
Pre-setting
Comment
DHCP Inactive
IP-address 192.168.10.22
Subnet Mask
255.255.255.0
Gateway address
192.168.10.254
Network
parameter
Root password
Ixxat
Protected by
password
Baud rate for RS232
19200
Hardware
parameter
Delay time (in seconds)
in the configuration
dialog
10
Access to manu-
facturer specific
parameters
Protected by
password
Firmware
update
3.2 Starting the configuration
To start the configuration, a terminal program must be connected with the
CAN@net via the first serial interface with Power on (pre-setting: 19200 Baud, 8
bits, no parity, 1 stop bit). A key must be pressed after the greeting text within
the start-up delay time (pre-setting 10s).
The configuration dialog is started by asking the user whether he wishes to mod-
ify the configuration:
Press A to Accept the settings, or M to Modify [M]?
With 'A'+<RETURN>, the dialog is exited and the CAN@net continues with the
initialization.
With 'M'+<RETURN>, the other dialogs can be accessed.
With all dialogs, if the <RETURN> key alone is pressed, the suggested values in
the square brackets [ ] are accepted.
Copyright IXXAT Automation GmbH
CAN@net Manual, Version 1.7