CAN@net II/Generic, Version 1.5
Web Interface
25
II/Generic actually applies on received CAN messages. With a power cycle, this
filter list in RAM will vanish and will be replaced by the filter list previously stored
in Flash.
By clicking on the "Save" button, the actual filter list will be stored from RAM to
Flash and will be available after the next power cycle. Or, by clicking the "Load"
button, the filter list from flash can be restored, overwriting the filter list in RAM.
Screenshot 5.4 Filter configuration
Filter configuration steps:
1. The "Load" button is used to restore the last saved filter list configuration.
Use the "Clear" button to erase the actual used filter configuration.
2. To add/remove or search for an ID, enter the ID in the field of step 2. More
than one ID can be entered by separating them by a space (e.g."2 b f 10
11"). The ID must be entered as a hexadecimal value (without a "0x"
prefix).