Device configuration steps:
1. If the CAN@net II/Generic should act as ASCII-Protocol server, choose
server and proceed with step 3. If the CAN@net II/Generic should be
configured as a client, choose client and proceed with step 2.
2. Under the header "Configure client" there are the settings that must be
given when a CAN@net II/Generic should act as client in a bridge
configuration as described in 2.2 Bridge setup. If a valid IP address is
entered here, the CAN@net II/Generic will act as client in a bridge
configuration. It will use the "IP address of Server” as IP address of the
ASCII-Protocol server it will connect to. When acting as a client, the
CAN baud rates for both the client and the server must be specified.
You can click on the checkbox “Use Heartbeat” to enable a heartbeat
mechanism. The heartbeat will test the connection of the bridge every
three seconds. If the connection is faulty for 6 seconds the devices are
rebooted and the connection is reattempted.