Use of Automatic Lifting Magnet LI-120 

 
Indication Lights and Functions 
 

 

 

 

 

 

Function of device / mode 

Indication light / lights 

Use of device 

Power OFF 

No lights 

No functions 

Start-up 

Two green lights are blinking for 3 
seconds 

Normal use 

Not starting 

Blue Light blinks once 

 
Operating temperature too low 
 

Magnet ON (attached) 

Green blinking light 

Normal use 

Magnet OFF (released) 

Red blinking light 

Normal use 

Low battery voltage 

Yellow blinking light 

Connect the device to the battery charger 

Charging 

Yellow light 

Wait until the battery is fully charged, then 
the device returns to normal functional 
mode 

Battery status check 

Blue light and Green blinking light, 2 to 9 
times 

Wait until the device returns to normal 
functional mode 

To reduce power consumption Automatic Lifter

 

LI-120 shuts down automatically when it is left unused for 60 minutes. After this LI-

120 can be restarted normally. 
 
Magnet is reset by pressing both buttons for 10 seconds 

 
 
Residual magnetism 
 

When Automatic Lifting Magnet LI-120 is either released from the load or shut down, the magnet's lifting 
surface has a residual magnetic force. This residual magnetic force may lift a piece of 5 kg depending on the 
shape and material of the piece. 
 
Due to residual magnetism Automatic Lifting Magnet LI-120 may collect pieces and particles not meant to be 
lifted. Please consider the residual magnetism of Automatic Lifting Magnet LI-120 when transporting, using, 
maintaining and storing the device. 
 

 Due to residual magnetism the device may lift light pieces when the magnet is released, but full 

holding force is not in use. Ensure always before lifting that the load is attached to the magnet and is 
confirmed by the green blinking indication light. 

 Due to residual magnetism, magnetic particles and pieces may get attached to the magnet's 

lifting surface; these will reduce the holding force during the lift. 

 

Automatic Lifter LI-120 has an automatic demagnetization feature which is activated when the device senses 
the lifting shaft elevation in magnet's OFF-state. Due to demagnetization, less force is needed to release the 
load from magnet. Demagnetization stays active for 0.5 seconds. 

Summary of Contents for LI-120

Page 1: ...Ixtur Oy Varespellontie 6 FI 21500 KAARINA FINLAND www ixtur com USER MANUAL Automatic Lifting Magnet LI 120 2014 V1 2...

Page 2: ...res Holding Force and Lifting Capacity Material Properties Air Gap and Surface Quality Material Thickness Use of Automatic Lifting Magnet LI 120 Indication Lights and Functions Residual Magnetism Prod...

Page 3: ...tions local regulations and national safety regulations related to lifting and lifting equipment Never leave the operating device unattended despite the holding force in circumstances when the load mi...

Page 4: ...with loads made of ferromagnetic materials Automatic Lifter LI 120 activates the magnetic lifting surface only with a sufficiently small air gap Automatic Lifter LI 120 leaves the magnet in its latest...

Page 5: ...nd splash water Charging time max 2 h Operational time with fully charged battery 100 hours in standby mode or 3000 magnet activations ON or OFF 1 2 9 8 10 3 5 4 6 7 1 Lifting shackle 2 Lifting shaft...

Page 6: ...ce Quality Read carefully the characteristics related to the magnet s lifting capacity before deployment of Automatic Lifting Magnet LI 120 Lifting capacity of the device must not be exceeded The devi...

Page 7: ...ue to rust on the load surface foreign particles such as metal chips from welding corrosion and convexity or concaveness of the surface Before magnet attachment both the magnet s lifting surface and t...

Page 8: ...ickness of steel plate When the thickness becomes smaller than this threshold the conducting capacity of steel plate weakens and at the same time the holding force is reduced When steel plate thicknes...

Page 9: ...sm When Automatic Lifting Magnet LI 120 is either released from the load or shut down the magnet s lifting surface has a residual magnetic force This residual magnetic force may lift a piece of 5 kg d...

Page 10: ...haft and the magnet s latest state remains for example magnet ON attached When the yellow indication light is blinking move the device near to the battery charger and start recharging as soon as possi...

Page 11: ...othly 6 After the lift set Automatic Lifting Magnet LI 120 and the attached load down carefully and smoothly Move the device downwards until the lifting shaft is released to DOWN position 7 The magnet...

Page 12: ...to magnet OFF released during the lift Do not detach the lifting shackle of the device when you connect the device to the crane Ensure always before lifting that the magnet state is ON attached i e g...

Page 13: ...s Clean and grease the lifting shaft with vaseline if necessary Do not use oil Remove all dents and spurs on the magnetic lifting surface 7 that can cause increasing air gap and decreasing holding for...

Page 14: ...as electronic components and a battery During the decommissioning of Automatic Lifting Magnet LI 120 follow local regulations for electronic device recycling Patent Pending Several Patent applications...

Page 15: ...VAT FI23186135 Contact information Varespellontie 6 FI 21500 KAARINA Finland www ixtur com Description of the product The product is lifting equipment which is meant to elevate magnetic metals and man...

Reviews: