e n g l i s h
|
8
Ixtur LI-120
Use of Automatic Lifting Magnet LI-120
Indication Lights and Functions
Function of device / mode
Indication light / lights
Use of device
Power OFF
No lights
No functions
Start-up
Two green lights are blinking for 3
seconds
Normal use
Not starting
Blue Light blinks once
Operating temperature too low
Magnet ON (attached)
Green blinking light
Normal use
Magnet OFF (released)
Red blinking light
Normal use
Low battery voltage
Yellow blinking light
Connect the device to the battery charger
Charging
Yellow light
Wait until the battery is fully charged, then
the device returns to normal functional
mode
Battery status check
Blue light and Green blinking light, 2 to 9
times
Wait until the device returns to normal
functional mode
To reduce power consumption Automatic Lifter
LI-120 shuts down automatically when it is left unused for 60 minutes. After this LI-
120 can be restarted normally.
Magnet is reset by pressing both buttons for 10 seconds
Residual magnetism
When Automatic Lifting Magnet LI-120 is either released from the load or shut down, the magnet's lifting
surface has a residual magnetic force. This residual magnetic force may lift a piece of 5 kg depending on the
shape and material of the piece.
Due to residual magnetism Automatic Lifting Magnet LI-120 may collect pieces and particles not meant to be
lifted. Please consider the residual magnetism of Automatic Lifting Magnet LI-120 when transporting, using,
maintaining and storing the device.
Due to residual magnetism the device may lift light pieces when the magnet is released, but full
holding force is not in use. Ensure always before lifting that the load is attached to the magnet and is
confirmed by the green blinking indication light.
Due to residual magnetism, magnetic particles and pieces may get attached to the magnet's
lifting surface; these will reduce the holding force during the lift.
Automatic Lifter LI-120 has an automatic demagnetization feature which is activated when the device senses
the lifting shaft elevation in magnet's OFF-state. Due to demagnetization, less force is needed to release the
load from magnet. Demagnetization stays active for 0.5 seconds.