Lifting shaft in DOWN-position: 
When elevation does not load the shaft, the lock spring is no longer restrained, 
and the shaft returns to DOWN-position. 

 

When the lifting shaft is released (i.e. when the shaft moves from UP-position to DOWN-position), the device 
senses movement and changes the state of the magnet. At all other times the state is either 'magnet ON' 
(attached) or 'magnet OFF' (released). 
 
Operation instructions  
 

1.  Follow carefully the safety instructions when you connect Automatic Lifting Magnet LI-120 lifting 

shackle to the crane. 

2.  Turn the power ON by pressing the right operation button for 3 seconds. Wait until the device is in 

normal use state and start-up indication lights are no more shown. 

3.  Check that the magnet state of the device is OFF (released)

 

i.e.

 

red indication light is blinking. Move 

the crane down and place Automatic Lifting Magnet LI-120 on the load surface. Move the device 
downwards until the lifting shaft is released to DOWN-position.  

4.  The magnet state changes automatically to 'magnet ON' (attached). 
5.  Check that the green indication light is blinking, to ensure that the load is attached before you lift the 

load. Ensure there is adequate holding force before lifting, and move the load smoothly. 

6.  After the lift, set Automatic Lifting Magnet LI-120 and the attached load down carefully and smoothly. 

Move the device downwards until the lifting shaft is released to DOWN-position.  

7.  The magnet state changes automatically to 'magnet OFF' (released). 
8.  Check that the red indication light is blinking, to ensure that the load is released. Lift the device slightly 

off the load.  

 
When the magnet is OFF (released), Automatic Lifting Magnet LI-120 has residual magnetic force, which can 
lift smaller pieces. To detach the load with less force, Automatic Lifting Magnet LI-120 activates its automatic 
demagnetization feature. When the device is lifted off the load, the device senses lifting shaft elevation. See 
chapter 'Residual Magnetism' earlier in this manual. 
 

 Do not detach the lifting shackle from the device when you connect the device to the crane. 

 Ensure always before lifting that the magnet state is ON (attached) i.e.

 

green indication light is 

blinking. 
 

 

Manual Use 
 

Automatic Lifting Magnet LI-120 must be connected to the crane with its lifting shackle in both manual and 
automated use. 

 

 

Automatic Lifting Magnet LI-120 is operated manually by using the left operation button.  
 
When the operator presses the operation button, the magnetic state changes. At all other times the state is 
either 'magnet ON' (attached) or 'magnet OFF' (released). Indication lights show the magnet state: 

 

Green blinking light = magnet ON (attached) 
Red blinking light = magnet OFF (released) 

Summary of Contents for LI-120

Page 1: ...Ixtur Oy Varespellontie 6 FI 21500 KAARINA FINLAND www ixtur com USER MANUAL Automatic Lifting Magnet LI 120 2014 V1 2...

Page 2: ...res Holding Force and Lifting Capacity Material Properties Air Gap and Surface Quality Material Thickness Use of Automatic Lifting Magnet LI 120 Indication Lights and Functions Residual Magnetism Prod...

Page 3: ...tions local regulations and national safety regulations related to lifting and lifting equipment Never leave the operating device unattended despite the holding force in circumstances when the load mi...

Page 4: ...with loads made of ferromagnetic materials Automatic Lifter LI 120 activates the magnetic lifting surface only with a sufficiently small air gap Automatic Lifter LI 120 leaves the magnet in its latest...

Page 5: ...nd splash water Charging time max 2 h Operational time with fully charged battery 100 hours in standby mode or 3000 magnet activations ON or OFF 1 2 9 8 10 3 5 4 6 7 1 Lifting shackle 2 Lifting shaft...

Page 6: ...ce Quality Read carefully the characteristics related to the magnet s lifting capacity before deployment of Automatic Lifting Magnet LI 120 Lifting capacity of the device must not be exceeded The devi...

Page 7: ...ue to rust on the load surface foreign particles such as metal chips from welding corrosion and convexity or concaveness of the surface Before magnet attachment both the magnet s lifting surface and t...

Page 8: ...ickness of steel plate When the thickness becomes smaller than this threshold the conducting capacity of steel plate weakens and at the same time the holding force is reduced When steel plate thicknes...

Page 9: ...sm When Automatic Lifting Magnet LI 120 is either released from the load or shut down the magnet s lifting surface has a residual magnetic force This residual magnetic force may lift a piece of 5 kg d...

Page 10: ...haft and the magnet s latest state remains for example magnet ON attached When the yellow indication light is blinking move the device near to the battery charger and start recharging as soon as possi...

Page 11: ...othly 6 After the lift set Automatic Lifting Magnet LI 120 and the attached load down carefully and smoothly Move the device downwards until the lifting shaft is released to DOWN position 7 The magnet...

Page 12: ...to magnet OFF released during the lift Do not detach the lifting shackle of the device when you connect the device to the crane Ensure always before lifting that the magnet state is ON attached i e g...

Page 13: ...s Clean and grease the lifting shaft with vaseline if necessary Do not use oil Remove all dents and spurs on the magnetic lifting surface 7 that can cause increasing air gap and decreasing holding for...

Page 14: ...as electronic components and a battery During the decommissioning of Automatic Lifting Magnet LI 120 follow local regulations for electronic device recycling Patent Pending Several Patent applications...