Check the rigid epoxy of the encapsulated coil on the magnetic lifting surface (7). If any parts of the 

coil are visible, take the magnet off service and contact Ixtur Ltd or your service technician 

 

Yearly Check 
 
It is recommended that the lifting capacity should be tested at least once a year by an authorized technician. 

 

 

Decommissioning of Automatic Lifter LI-120 

 

The device has electronic components and a battery. During the decommissioning of Automatic Lifting Magnet 
LI-120, follow local regulations for electronic device recycling. 

 

Patent Pending 

 
Several Patent applications pending to protect the product Automatic Lifting Magnet LI-120 
 

EC Declaration of Conformity 

 
We hereby declare that designing, manufacturing and testing of the product Automatic Lifting Magnet LI-120 
complies with the Directives and Standards listed below 

-

  Directives 2004/108/EC and 2006/42/EC 

-

  Standards EN 61000-6-1:2007, EN 61000-6-3+A1:2011, EN ISO 12100:2010, ISO/TR 14121:2007 

and EN 13155:2003+A2:2009 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LI-120

Page 1: ...Ixtur Oy Varespellontie 6 FI 21500 KAARINA FINLAND www ixtur com USER MANUAL Automatic Lifting Magnet LI 120 2014 V1 2...

Page 2: ...res Holding Force and Lifting Capacity Material Properties Air Gap and Surface Quality Material Thickness Use of Automatic Lifting Magnet LI 120 Indication Lights and Functions Residual Magnetism Prod...

Page 3: ...tions local regulations and national safety regulations related to lifting and lifting equipment Never leave the operating device unattended despite the holding force in circumstances when the load mi...

Page 4: ...with loads made of ferromagnetic materials Automatic Lifter LI 120 activates the magnetic lifting surface only with a sufficiently small air gap Automatic Lifter LI 120 leaves the magnet in its latest...

Page 5: ...nd splash water Charging time max 2 h Operational time with fully charged battery 100 hours in standby mode or 3000 magnet activations ON or OFF 1 2 9 8 10 3 5 4 6 7 1 Lifting shackle 2 Lifting shaft...

Page 6: ...ce Quality Read carefully the characteristics related to the magnet s lifting capacity before deployment of Automatic Lifting Magnet LI 120 Lifting capacity of the device must not be exceeded The devi...

Page 7: ...ue to rust on the load surface foreign particles such as metal chips from welding corrosion and convexity or concaveness of the surface Before magnet attachment both the magnet s lifting surface and t...

Page 8: ...ickness of steel plate When the thickness becomes smaller than this threshold the conducting capacity of steel plate weakens and at the same time the holding force is reduced When steel plate thicknes...

Page 9: ...sm When Automatic Lifting Magnet LI 120 is either released from the load or shut down the magnet s lifting surface has a residual magnetic force This residual magnetic force may lift a piece of 5 kg d...

Page 10: ...haft and the magnet s latest state remains for example magnet ON attached When the yellow indication light is blinking move the device near to the battery charger and start recharging as soon as possi...

Page 11: ...othly 6 After the lift set Automatic Lifting Magnet LI 120 and the attached load down carefully and smoothly Move the device downwards until the lifting shaft is released to DOWN position 7 The magnet...

Page 12: ...to magnet OFF released during the lift Do not detach the lifting shackle of the device when you connect the device to the crane Ensure always before lifting that the magnet state is ON attached i e g...

Page 13: ...s Clean and grease the lifting shaft with vaseline if necessary Do not use oil Remove all dents and spurs on the magnetic lifting surface 7 that can cause increasing air gap and decreasing holding for...

Page 14: ...as electronic components and a battery During the decommissioning of Automatic Lifting Magnet LI 120 follow local regulations for electronic device recycling Patent Pending Several Patent applications...

Page 15: ...VAT FI23186135 Contact information Varespellontie 6 FI 21500 KAARINA Finland www ixtur com Description of the product The product is lifting equipment which is meant to elevate magnetic metals and man...

Reviews: