Floor Configuration
GS Series
Optional Mixer
Control Panel
Junction Box &
Tank Penetration
GFCI Protected
Source Power
GS Mixer
Exterior Conduit and 3-Conductor Power
Cable (2-Power + 1-Ground)
GS mixer resting on tank floor under hatch.
Retrieval chain attached to mixer. Slots
aligned parallel with line extending from cen-
ter of tank to tank wall.
Junction box & roof
mount cable fixture
supplied with GS mixer
and located within
arms reach of the
hatch.
Terminate conduit
using flex conduit with
male thread end for
panel mount
Chain and cable
attached to quick link
Cord ran through cord
seal.
Locate power source receptacle and flex con-
duit termination at customer preferred location
of mixer control panel
Terminate conduit using flex conduit with male
thread end for panel mount
IMPORTANT
It is important to disinfect all components in contact
with potable water. There may be additional decon-
tamination procedures required, so it is important to
understand what procedures are acceptable. Decon-
tamination should be performed right before the unit
is lowered through the hatch. The mixer should be
immersed in water shortly after having been decon-
taminated to prevent corrosion caused by contact
with chlorine or alternate disinfectant.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Placement
1916_10006_20200514
O&M_GS12_120V_1PH_10025_20200811 - 9