Hatch Requirement
A 12 inch (305 mm) diameter hatch opening is required
to fit the GS Mixer through.
Power Requirement
120 VAC, 20 amp GFCI protected service and means
of quick power disconnect recommended.
Figure 1:
Typical GS Placement
Optional
Mixer Control Panel
Optional Customer
SCADA
120 VAC, 20Amp
GFCI Circuit Breaker
RATING
FULL
LOAD
MAXIMUM
LOAD
WINDING (1)
RES. IN OHMS
EFFICIENCY
%
POWER
FACTOR %
LOCKED
ROTOR
AMPS
KVA
CODE
HP
KW VOLTS
HZ
S.F.
(2)
AMPS WATTS
(2)
AMPS WATTS
M=MAIN RES.
S=START RES.
F.L.
S.F.
F.L.
S.F.
1/2
0.37
115
60
1.6
7.9
910
9.8
1120
1.4-2.0
42
54
99
99
28
H
Service Entrance to Motor - Maximum Length In Feet
Based on Service Factor Amps, and 5% Voltage Drop
Motor Rating
60° C and 75° C Insulation - AWG Copper Wire Size
Volts
HP
kW
14
12
10
8
6
4
3
2
1
0
00
000
0000
115
1/2
0.37
100
160
250
390
620
960
1190
1460
1780
2160
2630
3140 3770
{
Remove Power
Cord for Conduit
Connection
Junction Box & Cord Fixture
supplied with GS Mixer.
Located within arms reach
of the hatch.
Exterior Conduit and
3-Conductor Power Cable
(2-Power + 1-Ground)
Terminate conduit using flex
conduit with male thread end
for panel mount.