Step 1
Isolate power to the GS mixer to prevent it from turning on
during inspection. The mixer must be off to perform this
inspection safely.
Step 2
Remove white end plate on the end of GS Mixer. The side
that should be removed is the side without the screen on it.
You will find four (4) screws that will need to be removed in
order for the end plate to become free from the mixer.
(See Figure 1)
Step 3
Visually inspect the impeller for debris or build up. You
should be able to move the impeller freely with no resistance.
(See Figure 2)
Step 4
Remove any debris if necessary.
Step 5
Place the white end plate back on the GS Mixer, ensuring
to line up the notch on the top side of the mixer. The four
screws that were removed in Step 2 should be put back in
place at this point as well.
Tools Needed
1. Electric Drill
2. #3 Phillips drill bit
GS Mixer End Plate Removal and Impeller Visual
Figure 2:
Impeller View
Figure 1:
End Plate Removal
Impeller
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Troubleshooting
Troubleshooting
GS Series
1930_10004_20200811
O&M_GS12_120V_1PH_10025_20200811 - 14