HU
EN
t
(
s
)
0
I
(
A
)
Loosen the
welding gun
switch
Press and hold the welding
gun switch
t1
t4
t5
Arc is
ignited
Arc is
turned off
t2
t3
Welding current Is
The setting base
current Ib
2T operation:
This function without the adjustment of start current and crater current is suitable for the Re-tack
welding, transient welding, thin plate welding and so on.
● 0:
Press the gun switch and hold it. Electromagnetic gas valve is turned on. The shielding
gas stars to flow.
● 0~t1:
Pre-gas time (0.0-2 sec)
● t1~t2:
Arc is ignited (t1) and the output current rises (t2) to the setting welding current (Iw or
Ib) from the min welding current.
(0.0-10 sec)
● t2~t3:
During the whole welding process, the gun switch is pressed and held without releas-
ing.
Note
:
Select the pulsed output, the base current and welding current will be outputted
alternately; otherwise, output the setting value of welding current;
● t3:
Release the gun switch, the welding current will drop in accordance with the se-
lected down-slope time.
● t3~t4:
The current drops to the minimum welding current from the setting current (Iw or Ib),
and then arc is turned off.
(0.0-10 sec)
● t4~t5:
Post-gas time, after the arc is turned off. You can adjust it through turning the knob
on the front panel.
(0.0-10 sec)
● t5:
electromagnetic gas valve turned off, the shield gas stops to flow, and welding is
finished.
13