EN
3.3
HF/LIFT TIG display introduction
1.
Welding mode button
Press it to enter HF TIG or Lift TIG welding mode.
2.
Output waveform button
Press it to select DC output or AC wave output.
3.
Trigger mode button:
Press it to select 2T or 4T trigger mode.
4.
Welding function button
Press it to select No Pulse/ Pulse/ Spot welding function.
(Here is no Spot function in Lift TIG welding mode.)
5.
Parameter “A” button
Press it to select AC Balance. Setting range: -5 to +5.
6.
Parameter “B” button
Press it to select AC Frequency. Setting range:
50~250Hz.
7.
Function “A” button
Press it to select Pre-gas time, Start arc current and Up
slope time.
8.
Function “B” button
Press it to select Down slope time, End arc current and
Post-gas time.
9.
Parameters select/adjust
knob:
Press it to select welding current and other param-
eters. Rotate it to adjust parameters’ value.
10. Current display
It displays welding current during welding operation,
otherwise show current selected.
11.
Welding voltage display
It displays welding voltage.
SAVE
LOAD
P
OWER
F
ACTOR
C
ORRECTION
1
2
3
4
7
10
5
9
6
11
8
11
10