1
Cutting current regulator: it is used to regulate the current when cutting.
2
Power pilot lamp
3
Alarm pilot lamp (over-heat, over-current): This pilot lamp on, when the pro-
tection of the machine has been activated.
4
Cutting gun improper installation and air pressure low alarm
(1)when short circuit occurred between the electrode and the nozzle for
normal reasons, the lamp on , air feeds intermittently.
(2)when cutting gun with no electrode and nozzle installed, the lamp on, air
feeds intermittently.
(3)when the Shield Cup is not installed, the lamp flashes.
(4)when the air low, the lamp on .
5
READY (DC Indicator): Indicator is ON when DC output circuit is active.
6
RUN/SET: when cutting the workpiece, turn to the “RUN”; when doing gas
test, turn to the “SET”.
7
Positive output cable: connected to the workpiece
8
Cutting gun connector: connected to the cutting machine
9
Remote control plug: Connection to CNC plug.
10
Air inlet connector - Pressure regulator with manometer
11
Main cable: Connected to the appreciate power supply
12
Power switch: turn on or off the power source
3-2.
Operation steps of cutting
● After checking all connections, turn on the plasma cutting machine.
● Adjust the power to the thickness you intend to cut.
● Press the cutting switch on the torch, you shall have compressed air coming out of
the nozzle: within 2 seconds the pilot arc will be ignited.
● Get closer to the material, then the pilot arc will be switched automatically to cut-
ting arc.
● As you pull away the torch from the metal sheet, the cutting arc will be switched
back to pilot arc again.
● Now the machine is ready to use for cutting.
● When you release the cutting switch the arc will be shut down immediately.
● After the arc stopped for about 30 sec you will still have air flow from the nozzle to
cool the hot system elements.
EN-8