3.2
Environmental Characteristics
3.2.1
Environmental Specification
The below table provides the Environment specification of i.MX6UL/i.MX6ULL SODIMM SOM.
Table 11: Environmental Specification
Parameters
Min
Max
Operating temperature range (Industrial)
¹
-40°C
85°C
Operating temperature range (Commercial)
¹
0°C
70°C
¹ iWave guarantees the component selection for the given operating temperature. The operating temperature at the
system level will be affected by the various system components like carrier board and its components, system enclosure,
air circulation in the system, system power supply etc. Based on the system design, specific heat dissipating approach
might be required from system to system. It is recommended to do the necessary system level thermal simulation and
find necessary thermal solution in the system before using this board in the end application.
3.2.2
RoHS Compliance
iWave’s
i.MX6UL/i.MX6ULL SODIMM SOM is designed by using RoHS compliant components and manufactured on
lead free production process.
3.2.3
Electrostatic Discharge
iWave’s
i.MX6UL/i.MX6ULL SODIMM SOM is sensitive to electro static discharge and so high voltages caused by static
electricity could damage some of the devices on board. It is packed with necessary protection while shipping. Do not
open or use the SOM except at an electrostatic free workstation.