59
Measuring Currents
As shown in the figure below, clamping the sensor around
the seven loops in a bundle allows the conductor to pass
through the sensor aperture eight times, which increases the
voltage of the output signal by a factor of eight.
Arrange loops radially.
200 mm or more
High-potential
side
Low-potential
side
(Grounded side)