27
The inspection is
completed.
Inspecting the Device Before Use
Inspecting appearance and functionality of the device
and condition of conductors to be measured
Yes
No
Yes
No
Provide power to the device. (p. 29)
Off or
blinking
Yes
Yes
No
2
Do not clamp the sensor
around any damaged
conductor.
Is the insulation of
each conductor to be
measured damaged?
Have the device repaired.
The device is damaged.
Do the seven LEDs
light up for about one
second after the device
is turned on?
Have the device repaired.
Damage can cause
electric shock.
Is the insulation of each
cord damaged?
Have the device repaired.
Damage can cause
electric shock.
Are the sensor, junction
box, and termination
unit damaged?