background image

3

EN

IMPROPER USE

 

1.   Never point gun towards people or animals.

2.     Never exceed maximum working pressure or maximum operating 

Temperature

3.   Always release air and fluid pressure before cleaning, disassembling 

or servicing.

 Otherwise, remaining pressure can cause bodily injury due to 

improper operation or scattering of cleaning liquid.

4.   Tip of fluid needle set has a sharp point. 

Do not touch the tip during maintenance to avoid accidents.

5.   Never use this gun to spray foods or chemicals. 

Otherwise, foreign sub-

stance, could cause corrosion of fluid passages which could adversely affect 
health.

6.   Never alter this spray gun, 

to avoid insufficient performance and damage.

7.   If something goes wrong, immediately stop operation and find the cause. 

Do not use again, until you have solved the problem.

8.   Do not enter working areas, where robots, reciprocators, etc. are used, 

until they have been turned off. 

Otherwise, they could cause injury.

3. HOW TO CONNECT

 CAUTION

-    Use clean air filtered through air dryer and air filter.

-    When using this gun for the first time after purchase, adjust fluid needle 

packing set, spray cleaner to clean fluid passages and remove rust pre-
ventive oil.

-   Firmly fix cup to spray gun, to avoid that disconnection of it, can cause 

bodily injury.

1.

  Firmly connect an air hose to air nipple G1/4” (17).

2.

  Firmly connect a suitable cup to fluid nipple G1/4”(15).

3.

  Flush fluid passages with a compatible cleaner.

4.

  Pour paint into container, test spray, adjust fluid output and pattern width.

4. HOW TO OPERATE

_  Suggested atomizing air pressure is 2.0 to 3.0 bar (29 to 44 PSI) at gun inlet.

_  Paint viscosity differs according to paint property and painting conditions.

_  Set the spray distance from the gun to the work piece, as near as possible 

within the range of 100-200 mm (3.9-7.9 in).

_  The gun should be held so that it is perpendicular to the surface of the  

 

 

workpiece at all times. Then, the gun should move in a straight and horizon-  

 

tal line. Arcing the gun causes uneven painting.

2. SAFETY WARNING

  FIRE AND EXPLOSION 

 

1.   Never use the following HALOGENATED HYDROCARBON SOLVENTS:

                                        

which can cause cracks or dissolution of gun body (aluminium) due to  

 

 chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 
1.2-dichloroethane, carbon tetrachloride,  trichloroethylene,   

 

1.1.1-trichloroethane                           

2.   Sparks and open flames are strictly prohibited.

 Paints can be highly  

 

 flammable and can cause fire. Do not expose to open flames, electrical  

 

 goods, cigarettes etc.

3.   Securely ground spray gun using conductive air hose. 

(Less than1M

:

Always ensure that the spray gun is earthed correctly.

PROTECTION OF HUMAN BODY

1.  Use in a well-ventilated site, using a spray booth.

 

Poor ventilation can cause organic solvent poisoning and fire.

2.   Always wear protective gear (safety glasses, mask, gloves) to avoid  

inflammation of eyes and skin.

  

In case of any physical discomfort, immediately seek medical advice.

3.   Wear earplugs if necessary.

 

Noise level can exceed 85 dB(A), depending on operating conditions and  
painting site.

4.   Pulling the trigger many times during operation, may cause carpal 

tunnel syndrome

. Always rest, in case of tiredness.

This  AIRGUNSA spray guns kit complies
to ATEX regulations 

2014/34/EU

Protection level: II 2G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to 
the ground via the conductive air hose as stipulated. 

ALWAYS observe WARNINGS and CAUTIONS in this 

 instruction 

manual.

Before use, adjustment or maintenance, it is important  
to read this instruction manual very carefully. 
This manual must be stored in a safe place for any future 
reference.

Symbol

WARNING

Hazard level

Consequence

WARNING

Potentially hazardous 
situation

Death or serious injury

CAUTION

Potentially hazardous 
situation

Minor to moderate injury

IMPORTANT

Potentially hazardous 
situation

Property damage

AZ3 HTE P.A.S.

1. TECHNICAL SPECIFICATIONS

Max. working air pressure: 

7.0 bar (100 PSI)

Max. air pressure inside cup:

1.5 bar (21.76 PSI)

Weight g (lbs): (without cup)

730 (1.61)

Noise level (LAeqT)*: 

77.6 dB(A)

Air Connection

G1/4”

Fluid Connection

G1/4”

Max. Temperature range: 

Atmosphere 5 ~ 40 °C / Air-Fluid 5 ~ 43 °C

* Measuring point: 1m backwards from gun, 1.6 m height.  

Reviews: