4. Disassembly and Assembly
(Foot mounted motor type)
- 42 -
Caution
• Since the magnet used in the pump is very powerful, be careful not to get your fingers
caught between the elements during the disassembly and assembly processes. Also, pay
attention to prevent metal pieces or metal powder from adhering onto the pump.
• Do not bring any electronic device that may be impacted by strong magnetic power into the
pump magnetic field.
• Prior to disassembly or assembly, close the suction valve and discharge valve fully.
• The piping and the pump often retain liquid. When a dangerous liquid is handled, wear
protectors (goggles, rubber gloves, etc.) when disconnecting the pipes.
b
b
Disassembly
[1] Disassemble only after thoroughly washing out the
liquid inside the pump by use of flushing piping, if
pump has drainport, remove the hex bolt (901.1) and
drain plate (122) and drain the liquid out of the casing.
Then, clean the inside of the pump.
Warning
Wear protectors (goggles, rubber gloves, etc.).
Certain liquids are dangerous. They may hurt your
eyes and skin.
[2] Remove the coupling cover bolts (901.5) and detach
the coupling cover (681). Next, remove the coupling
bolt and coupling spacer.
Coupling spacer
[3] Remove the hex head bolt (901.3) which fastens the
support (183) of the bearing housing (350). Then
remove the hex head bolt (901.8) and the nuts (920) on
the front casing side.