background image

T751 '10/12

(   )Country codes

IWAKI CO.,LTD.

 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan

TEL:(81)3 3254 2935 FAX:3 3252 8892(http://www.iwakipumps.jp)

Australia IWAKI Pumps Australia Pty. Ltd.

TEL : (61)2 9899 2411 FAX : 2 9899 2421

Italy

IWAKI Italia S.R.L.

TEL : (39)0444 371115 FAX : 0444 335350

Austria

IWAKI (Austria) GmbH

TEL : (43)2236 33469 FAX : 2236 33469

Korea

IWAKI Korea Co.,Ltd.

TEL : (82)2 2630 4800 FAX : 2 2630 4801

Belgium IWAKI Belgium n.v.

TEL : (32)1367 0200

FAX : 1367 2030

Malaysia IWAKIm Sdn. Bhd.

TEL : (60)3 7803 8807 FAX : 3 7803 4800

China

IWAKI Pumps (Shanghai) Co., Ltd.

TEL : (86)21 6272 7502 FAX : 21 6272 6929

Norway

IWAKI Norge AS

TEL : (47)66 81 16 60 FAX : 66 81 16 61

China

IWAKI Pumps (Guandong) Co., Ltd.

TEL : (86)750 3866228 FAX : 750 3866278

Singapore IWAKI Singapore Pte. Ltd.

TEL : (65)6316 2028 FAX : 6316 3221

China

GFTZ IWAKI Engineering & Trading (Guangzhou)

TEL : (86)20 8435 0603 FAX : 20 8435 9181

Spain

IWAKI Iberica Pumps, S.A.

TEL : (34)943 630030 FAX : 943 628799

China

GFTZ IWAKI Engineering & Trading (Beijing)

TEL : (86)10 6442 7713 FAX : 10 6442 7712

Sweden

IWAKI Sverige AB

TEL : (46)8 511 72900 FAX : 8 511 72922

Denmark IWAKI Nordic A/S

TEL : (45)48 24 2345 FAX : 48 24 2346

Switzerland IWAKI (Schweiz) AG

TEL : (41)26 674 9300 FAX : 26 674 9302

Finland

IWAKI Suomi Oy

TEL : (358)9 2745810 FAX : 9 2742715

Taiwan

IWAKI Pumps Taiwan Co., Ltd.

TEL : (886)2 8227 6900 FAX : 2 8227 6818

France

IWAKI France S.A.

TEL : (33)1 69 63 33 70 FAX : 1 64 49 92 73

Taiwan

IWAKI Pumps Taiwan (Hsin-chu) Co., Ltd.

TEL : (886)3 573 5797 FAX : (886)3 573 5798

Germany IWAKI EUROPE GmbH

TEL : (49)2154 9254 0 FAX : 2154 9254 48

Thailand IWAKI (Thailand) Co.,Ltd.

TEL : (66)2 322 2471 FAX : 2 322 2477

Holland IWAKI EUROPE NL Branch

TEL : (31)547 293 160 FAX : 547 292 332

U.K.

IWAKI Pumps (UK) LTD.

TEL : (44)1743 231363 FAX : 1743 366507

Hong Kong IWAKI Pumps Co., Ltd.

TEL : (852)2 607 1168 FAX : 2 607 1000

U.S.A.

IWAKI AMERICA Inc.

TEL : (1)508 429 1440 FAX : 508 429 1386

Indonesia IWAKI Singapore (Indonesia Branch)

TEL : (62)21 690 6606 FAX : 21 690 6612

Vietnam IWAKI pumps Vietnam Co.,Ltd.

TEL : (84)613 933456 FAX : 613 933399

Summary of Contents for APN-085-W

Page 1: ...Read this manual before use of product APN 085 W Instruction Manual IWAKI Gas Liquid Transfer Pump...

Page 2: ...fully for the prevention of personnel injury or property damage Observe the instructions accompanied with WARNING or CAUTION in this manual These instructions are very impor tant for protecting pump u...

Page 3: ...o as not to take in toxic fume during pipework or dismantlement Specified power only Do not apply any power other than the speci fied one on the nameplate Otherwise dam age or fire may result Restrict...

Page 4: ...ited Electrical shock Electrical shock Prohibited CAUTION CAUTION Safety Instructions Damaged pumps Do not use any damaged pump Using a damaged pump may lead to an electric leak or shock Stop operatio...

Page 5: ...e use check the specification limitation and hazardous nature of the pump 1 Unpacking Inspection On unpacking the product check the following points If you find any problems contact your nearest distr...

Page 6: ...t W Rated current A Thread APN 085E 3 0 05 34 66 48 20 0 22 Rc1 8 2 5 5 APN 085V 37 33 APN P085E 5 34 66 2 8 APN P085V 37 33 NOTE1 Observe the maximum discharge pressure of 0 05MPa NOTE2 Allowable gas...

Page 7: ...6 APN 085E 21 33 7 99 101 32 47 99 61 32 74 66 87 99 0 1 2 3 4 5 6 APN 085V Discharge pressure MPa AIR FLOW L min Vacuum pressure kPa abs 50Hz 7 99 47 99 21 33 34 66 74 66 87 99 61 32 101 32 0 0 05 1...

Page 8: ...et 2 7 Overview Label The illustration below shows an APN 085 W single head type Pump head Name plate Model and MFG No Production number are described Pump body Driven unit An installation location sh...

Page 9: ...4 3 2 38 79 APN P085 W No Part names Q ty No Part names Q ty 1 Pump head 2 20 Bracket 2 2 Valve 4 40 Motor 1 3 Valve seat 2 46 Capacitor 1 4 Diaphragm 2 62 Small screw 8 19 Connecting rod unit 2 set 7...

Page 10: ...d not fall below 0 C or exceed 40 C Observe the allowable gas temperature range of 0 and 40 C and liquid tempera ture range of 5 and 40 C 1 Before Installation Read through this instruction manual bef...

Page 11: ...Do not use the pump in a dusty place Be sure to provide the inlet with a filter to prevent foreign mat ters from getting into the pump Otherwise the pump performance may reduce or the lives of valves...

Page 12: ...ump baseplate on a con crete foundation and fasten cor rosion resistant M5 screws tightly to prevent the pump from vibrating during operation CAUTION Do not install the pump on a wobbly pedestal 2 2 T...

Page 13: ...s far as they will go NOTE If suction line connection is imperfect the pump sucks air and it prevents the pump from bringing out full per formance 2 3 Electrical wiring Electrical wiring must be done...

Page 14: ...Always use a suction valve to adjust an air liquid flow If the compressed air or liquid higher pressure than atmospheric pres sure is transferred to the pump sharp deterioration to the lives of the v...

Page 15: ...s 1 and 2 Turn on power and start the pump Smooth starting may not be obtained when ambient temperature is 10 C or below In this case run the pump with no discharge line pressure for a few minutes to...

Page 16: ...Release pressure and turn off main power Make sure both supply air and gas are stopped Before resuming operation Operation may occasionally be upset in the beginning In this case warm up the pump und...

Page 17: ...ge to the rated level Higher suction pressure than atmospheric Reduce suction pressure Condensation in the pump head Dry up the pump Contact us for the measures marked with 2 Maintenance Inspection Ha...

Page 18: ...e above lives are reference values and not warranted Cleaning Turn off power and wait until the pump has cooled down Then clean off the surface of the pump with a wet cloth Use a neu tral detergent fo...

Page 19: ...ear protective clothing such as a mask so as not to take in toxic fume during pipework or dismantlement See page 6 8 Part names Structure as necessary Diaphragm replacement 1 Unscrew the pump head fix...

Page 20: ...air is dis charged through the outlet 4 Push down the diaphragm until it bottoms out and then secure the unit onto the bracket with the screws by 1 37N m IN OUT Pump head Gasket Valve Valve seat NOTE...

Page 21: ...19...

Page 22: ...20...

Page 23: ...21...

Page 24: ...IWAKI Iberica Pumps S A TEL 34 943630030 FAX 943628799 China GFTZIWAKIEngineering Trading Beijing TEL 86 1064427713 FAX 1064427712 Sweden IWAKI Sverige AB TEL 46 851172900 FAX 851172922 Denmark IWAKI...

Reviews: