- 10 -
Installation
2. Installation/ Tubing/ Electrical wiring
2.1 Installation
1. Do not expose the pump to
direct sunlight, vibration and
wind & rain.
2. Keep good ventilation. The
pump should always be free
from the possibility of getting
wet.
3. Ambient temperature should
not fall below 0°C or exceed
40°C. Observe the allowable
maximum ambient humidity
of 90%RH.
4. Install the pump in a clear
and level place.
Select a convenient place
for maintenance and inspec-
tion.
5. Pump fixation
Set the pump baseplate on a con-
crete foundation and fasten cor-
rosion-resistant M5 screws tightly
to prevent the pump from vibrating
during operation.
CAUTION
Do not install the pump on a wobbly pedestal.
2.2 Tubing
1. The short tubing with the minimum bends is optimal to
reduce resistance.
2. Avoid sharp turns or bends.
CAUTION
Do not have tubing bent or pressed. Otherwise, the tube
end may break.
3. Tubes and fittings
Provide tube fittings to the threaded
inlet and outlet (Rc1/8) of the pump. Use
chemically-resistant tubes or tempera-
ture-/pressure-resistant braided tubes as
necessary. Cut the tube ends and have
them flat before insertion.
Stop working upon sensing danger or abnormality.
WARNING