Model
Recommended Heater Power (watt)
Room Area (m2)
EFP 4550 E25/M25
2500
15 - 30
The heat requirement depends on factors such as the exterior temperature, room
heat isolation, door open/close cycles. The values stated on the above table are for
average conditions with an outside temperature of 8-10 degrees therefore when
calculating the heater power these factors should be taken into consideration.
TECHNICAL SPECIFICATIONS
Circuit Diagram for Manual Electric Heater With Fan
F: Phase
N: Notr
Te1: Security Thermostat
Te2: Security Thermostat
SO: Rolover Protection Switch
R1: Resistans First Setting
R2: Resistans Second Setting
F1: Fan First Setting
F2: Fan Second Setting
L: Signal Lamp
Figure 2. Electrical Circuit Diagram for Manual
Fan Heater
SO
Manual Electric Heater With Fan
Type
EFP4550EM5
Height mm 450
Length mm 500
Depth mm 98
Weight kg
7
Electrical Power W 2300-2700
Voltage V
220-240
Current A
10.9
Frequency Hz
50-60
Electronic Room Temperature Control
-
Energy Saving Module
-
On / Off Switch
-
Cord Length m
2
Protection Type
I
Protection Against Water Spill (IP)
IP 24
Thermostat Against Excessive Heat
Disponible
Mechanical Thermostat Control
Disponible
Energy Consumption Display
-
Room Temperature Display
-
Fan
Disponible
Sound Level
dB
max.50
Color Choices
White (B)