WARNING CODES
Digştal Electric Fan Heater
Warning Code Description
Action
L
LDR calibration menu (This
warning appears when enter
-
ing the light calibration menu)
It is for you to make sure that you are in the
correct menu.
A
NTC calibration menu (This
warning appears when enter
-
ing the ambient temperature
calibration menu)
It is for you to make sure that you are in the
correct menu.
PE
Overheating warning for the
plug (This warning is activated
when the plug temperature
exceeds 80 degrees)
Immediately unplug the device and allow it
to cool down for 1-2 hours. The device can be
used again, but it is necessary not to use it in
the socket where the overheating occurred and
to have a qualified electrician check the plug
and replace the plug if necessary.
F1
Fan block warning. (This warn
-
ing is displayed if the outlet
NTC exceeds 150 degrees)
Immediately unplug the device and remove
any obstructions blocking the front or back
of the device. The device can be used again
by plugging it in after 10-15 minutes. If the
same warning is displayed even though the
obstacles have been removed, the technical
service should be contacted.
F2
Fan malfunction warning.
(This warning is displayed
if the outlet NTC exceeds 70
degrees and the ambient NTC
exceeds 50 degrees)
The device must be unplugged immediately
and the issue should be reported to the techni
-