IVDT SkidWeigh DL2E-EPSeries Installation & Calibration Manual Download Page 8

Operator Weighing Procedure 

   

                                                                                                                                                                                                                                                                                                              

                                          

                                                                                                                                                                                                                                                                                                                                

The 

Mode 8

  shown on LED display is always the 

starting point to initiate a weighing cycle 

 

Weighing Loads    

                                                                                                           

When power to the vehicle is turned on the LED display 
should show software version. 

(Example: Software version 1500)

          

                       

If the LED display is not showing any digits make sure the 
power on / off switch

 

located on top of the instrument 

enclosure is on.

 

                                                                                                                                                            

1.

 Insert the forks into the pallet or under the product to be 

weighed.                                                                                  

2.

 Lower the forks to the ground.                                                                                                                                                                                               

LED display must show Mode 8 to initiate the “weighing 
cycle”.

 

                                                                               

3.

 

Activate and hold the lift control button

. LED display 

will go blank for the moment, audio will be activated 
during the measurement.                                                                          

The “weighing cycle” will be initiated and the system will 

automatically stop the lift cylinder when ready and load weight will be shown.

 Audio will be deactivated.                                                                                                                                                                                                                                                           

The lift cylinder will be operational once the load weight is shown on the LED display.  

                           

                                                                               

Mobile Wireless Bluetooth Printer

  

 

The SkidWeigh ED2-EP / DL2-EP Elite series can be 
ordered to support Bluetooth mobile printers. The automatic 
Bluetooth pairing is done by holding down 

Arrow Up 

and 

turning power on to the system.Within few seconds the LED 
light (Blue) will come on and stay on indicating that pairing 
with mobile printer is completed. 

             

 

  

Accumulative Load Weight Function

  

                                                                                                                                           

SkidWeigh ED2E-EP-AT / DL2E-EP-AT

  Units equipped with the AT, accumulative totalling function, utilize 

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

www.skidweigh.com

 

  

Summary of Contents for SkidWeigh DL2E-EPSeries

Page 1: ...ual Electric Pallet Truck Check Weighing Systems SkidWeigh Series ED2E EP and DL2E EP ED2E EP V1500 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power On Off Switch ...

Page 2: ...er with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected ...

Page 3: ...r nal relay is controlled by the microprocessor and activated only during the load weighing cycle There is no power connected to these two BLACK wires Internal relay configuration is SPDT Method A Preferred Method Use the two BLACK wires to splice them in series with the operator activated lift control switch wire or signal wire from the electronic controller that is activating the lift pump motor...

Page 4: ...ed vehicle is motion may produce hydraulic spikes that are detected by the pressure transducer sending a signal this may be seen by the vehicle controller as starting the weighing cycle Short interruption of the power to the lift solenoid coil on some controllers are seen as a fault and power to the vehicle will be cut SkidWeigh ED2E EP DL2 EP Power Off When weighing function is not required and to...

Page 5: ...ower Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wire connected to the ignition switch Automotive 60 V load dump protection Reversal power supply protection Weighing Function Calibration Procedure The SkidWeigh ED2E EP DL2 EP calibration is automatic and is done by liftin...

Page 6: ...own for approximate 5 seconds After 5 seconds the Mode 8 digit will change to Mode 0 Press and hold the lift button to initiate the automatic weighing cycle Continue to hold until the system lift interrupt stops the lift range The system will develop an algorithm calculation and determine the correct height to stop the lift cylinder The LED display will go blank momentarily internal audio will be ...

Page 7: ... 5th least significant digit has 0 value entered into the calibration system With loaded forks on the ground and no pressure in the system press the M button to advance to Mode 6 When the digital indicator shows Mode 6 activate and hold lift control button The pressure transducer readings and specific algorithm calculations will stop the lift cylinder at predetermined height The LED display will g...

Page 8: ...the measurement The weighing cycle will be initiated and the system will automatically stop the lift cylinder when ready and load weight will be shown Audio will be deactivated The lift cylinder will be operational once the load weight is shown on the LED display Mobile Wireless Bluetooth Printer The SkidWeigh ED2 EP DL2 EP Elite series can be ordered to support Bluetooth mobile printers The autom...

Page 9: ...ED display until next time the forks are lowered to ground Note2 When vehicle in motion the LED might show some random load weight This is due to the hydraulic spikes and this does not represents any actual load weight value Note 3 During the normal operation if you do not want to use the weighing function turn off the main power switch located on the top of the housing LED display will not show an...

Reviews: