Selecting the Mounting Location for Digital Indicator
Use the mounting bracket with the anti vibration mounts and fasten the digital indicator to the vehicle dashboard, or any
other convenient place on the electric pallet truck body There are many examples of mounting locations that will depend
on the vehicle model. However, additional mounting items such as a flat brackets may be needed to help secure the unit.
Electrical Connections
All SkidWeigh systems operate from 12 to 55 VDC.
Orange Wire
(+) Key switch On position
Brown Wire
(-) Battery negative
Red Wire,
connect to RED wire of the pressure transducer cable
Black Wire,
connect to BLACK wire of the pressure transducer cable
White Wire,
connect to WHITE wire of the pressure transducer cable
Two
black wires
are connected to the internal relay located in the ED2E-EP / DL2-EP digital indicator. The internal
relay is controlled by the microprocessor and activate only during the load weighing cycle.
There is no power con-
nected to these two black wires.
Electrical Power Short Circuit Protection
- All SkidWeigh systems are internally short circuit protected with a resettable fuse. There is no need to install external
inline fuse in the orange wire connected to the ignition switch.
- Automotive 60 V load dump protection
- Reversal power supply protection
Weighing Function Calibration Procedure
The SkidWeigh ED2E-EP / DL2-EP
calibration is automatic and is done by lifting empty and loaded forks to
initiate and program the automatic weighing cycle.
MAKE SURE THAT YOU HAVE A KNOWN LOAD WEIGHT
AND KEEP IT NEARBY TO COMPLETE THE SYSTEMS CALIBRATION PROCESS.
For the best results use at least minimum calibration load test weight of 50% to 80% of maximum lifting capacity of the
electric pallet truck. Use floor scale or find a known load weight with a confirmed and trusted weight.
Important:
If you want the system to show load weight in pounds, use the known load weight in pounds and enter that
value accordingly. The same would apply if you want the system to show load weight in kilograms. Use the
known load weight in kilograms and enter that value into the system accordingly.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7