IVDT SkidWeigh DL2E-EPSeries Installation & Calibration Manual Download Page 5

Selecting the Mounting Location for Digital Indicator 

Use the mounting bracket with the anti vibration mounts and fasten the digital indicator to the vehicle dashboard, or any 
other convenient place on the electric pallet truck body There are many examples of mounting locations that will depend 
on the vehicle model. However, additional mounting items such as a flat brackets may be needed to help secure the unit.                                                                                                                                                                                                                      

Electrical Connections

All SkidWeigh systems operate from 12 to 55 VDC.

 

 

                                                                                                                                                   

Orange Wire 

(+) Key switch On position                                                                                                              

Brown Wire 

(-) Battery negative                                                                                                                                  

Red Wire,

 connect to RED wire of the pressure transducer cable                                                                                                

Black Wire,

 connect to BLACK wire of the pressure transducer cable                                                                                                                                               

                      

White Wire,

 connect to WHITE wire of the pressure transducer cable  

Two 

black wires 

are connected to the internal relay located in the ED2E-EP / DL2-EP digital indicator. The internal 

relay is controlled by the microprocessor and activate only during the load weighing cycle. 

There is no power con-

nected to these two black wires.

  

 

                                                                                                                  

                                                                  

Electrical Power Short Circuit Protection  

                                                                                                            

- All SkidWeigh systems are internally short circuit protected with a resettable fuse. There is no need to install external 
inline fuse in the orange wire connected to the ignition switch. 
- Automotive 60 V load dump protection                                                                                                                              
- Reversal power supply protection 

    

                                                                                                                                                                                                                                              

 

Weighing Function Calibration Procedure 

   

                                                                                                                                                    

The SkidWeigh ED2E-EP / DL2-EP 

calibration is automatic and is done by lifting empty and loaded forks to 

initiate and program the automatic weighing cycle. 

 MAKE SURE THAT YOU HAVE A KNOWN LOAD WEIGHT 

AND KEEP IT NEARBY TO COMPLETE THE SYSTEMS CALIBRATION PROCESS.                                                                                                                                                                                                                                                                                                                                                      

For the best results use at least minimum calibration load test weight  of 50% to 80% of maximum lifting capacity of the 
electric pallet truck. Use floor scale or find a known load weight with a confirmed and trusted weight.                                                                                                                   

Important:                                                                                                                                     

 

If you want the system to show load weight in pounds, use the known load weight in pounds and enter that 
value accordingly. The same would apply if you want the system to show load weight in kilograms. Use the 
known load weight in kilograms and enter that value into the system accordingly. 

Integrated Visual Data Technology Inc.  3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

 

www.skidweigh.com

 

  

Summary of Contents for SkidWeigh DL2E-EPSeries

Page 1: ...ual Electric Pallet Truck Check Weighing Systems SkidWeigh Series ED2E EP and DL2E EP ED2E EP V1500 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 www skidweigh com Power On Off Switch ...

Page 2: ...er with electro and hydraulic experience Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected ...

Page 3: ...r nal relay is controlled by the microprocessor and activated only during the load weighing cycle There is no power connected to these two BLACK wires Internal relay configuration is SPDT Method A Preferred Method Use the two BLACK wires to splice them in series with the operator activated lift control switch wire or signal wire from the electronic controller that is activating the lift pump motor...

Page 4: ...ed vehicle is motion may produce hydraulic spikes that are detected by the pressure transducer sending a signal this may be seen by the vehicle controller as starting the weighing cycle Short interruption of the power to the lift solenoid coil on some controllers are seen as a fault and power to the vehicle will be cut SkidWeigh ED2E EP DL2 EP Power Off When weighing function is not required and to...

Page 5: ...ower Short Circuit Protection All SkidWeigh systems are internally short circuit protected with a resettable fuse There is no need to install external inline fuse in the orange wire connected to the ignition switch Automotive 60 V load dump protection Reversal power supply protection Weighing Function Calibration Procedure The SkidWeigh ED2E EP DL2 EP calibration is automatic and is done by liftin...

Page 6: ...own for approximate 5 seconds After 5 seconds the Mode 8 digit will change to Mode 0 Press and hold the lift button to initiate the automatic weighing cycle Continue to hold until the system lift interrupt stops the lift range The system will develop an algorithm calculation and determine the correct height to stop the lift cylinder The LED display will go blank momentarily internal audio will be ...

Page 7: ... 5th least significant digit has 0 value entered into the calibration system With loaded forks on the ground and no pressure in the system press the M button to advance to Mode 6 When the digital indicator shows Mode 6 activate and hold lift control button The pressure transducer readings and specific algorithm calculations will stop the lift cylinder at predetermined height The LED display will g...

Page 8: ...the measurement The weighing cycle will be initiated and the system will automatically stop the lift cylinder when ready and load weight will be shown Audio will be deactivated The lift cylinder will be operational once the load weight is shown on the LED display Mobile Wireless Bluetooth Printer The SkidWeigh ED2 EP DL2 EP Elite series can be ordered to support Bluetooth mobile printers The autom...

Page 9: ...ED display until next time the forks are lowered to ground Note2 When vehicle in motion the LED might show some random load weight This is due to the hydraulic spikes and this does not represents any actual load weight value Note 3 During the normal operation if you do not want to use the weighing function turn off the main power switch located on the top of the housing LED display will not show an...