background image

 

Overload Alert Value Input

   

                                                                                      

                                                                                                                   

 

When

 SkidWeigh system weighing function calibration is completed, 

loaded forks must be 

lowered to ground.                                                                                 

                                       

The 

Mode 7 

digit automatically will be shown and will remain on LED display until overload alert 

value is inputed into the system. With LED display showing

 “Mode 7”

 you have to enter the 

overload alert value for that vehicle / application. In our example we will enter the overload alert 
value of 

4500

. Use paper clip to access buttons “M” and “Arrow Up”.Make sure

 0

 number is 

inputed for digit 5. 

(In our example for overload value of 4500 has only 4 digits) 

As soon the last digit is inputed into the system

 Mode 7

 will change to

 Mode 8 

which is the 

normal operational mode.  

                                                                                                                                                                                                                                                                

Note: If the lifted load is above preset overload value of 4500 the LCD display will                                                                                                                                                                                        

* Show actual overload value                                                                                                                                              
* LED display showing the overload value will “flash”                                                                                                                                                    
* Overload value will stop “flashing” when loaded forks are lowered to the ground   

Mode

Digit 5

Digit 4

Digit 3

Digit 2

Digit 1

7

0

7

0

7

5

7

4

7

0

Integrated Visual Data Technology Inc.,   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7

    

Summary of Contents for SkidWeigh Classic

Page 1: ... Classic Lift Truck Onboard Check Weighing Scale With Overload Alert SC Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Installation Calibration Operator Usage Guide ...

Page 2: ...roper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This product is connected directly to the vehicle s ignition switch 12 to 55 VDC There is no on off switch on the unit For vehicles with voltages higher than 55 VDC use voltage convertor 36 to 160 VDC Part...

Page 3: ...ering the lifting cylinder into its lowest position Be sure that chain s are slack Make sure that that installed pressure transducer will not touch any moving parts or assembly of the vehicle while in normal operation Pressure transducer has 1 4 18 NPT male thread Use thread seal to ensure tight fit Selecting the mounting location for digital indicator Use the mounting flange and fasten digital in...

Page 4: ...D display If the above test is valid then the system electrical connections are done right The next procedure will be to calibrate the SkidWeigh weighing function Use paper clip to access buttons M and Arrow Up Lift truck equipped with hydraulic accumulator If the standard SkidWeigh system is installed on the lift trucks equipped with hydraulic accumulators please contact us to provide you with di...

Page 5: ...To initiate calibration press the M key use a paper clip and hold it down for approx 5 seconds and Mode number 8 will change to number 0 System is ready for automatic zeroing of the scale function When LED display is showing 0 in Mode digit lift the empty forks just above the ground to automatically calibrate zero value for empty forks being lifted Activate the lift control valve as you would do d...

Page 6: ... arrow up button increments from 0 to 9 for each digit wrap around To move to next digit press M button Start with least significant digit In our case this is 0 Use M button to increment to the next digit on LED display To enter the second digit press the M button and Mode digit will increment to the second Keep pressing M button and enter a third forth and fifth values As the input for known load...

Page 7: ...ay will show the value of calibrated Known load weight of 4000 Lower the load to the ground System will go automatically into operational mode System is ready to be used Mode digit will display number 8 Note If system is set up for overload alert the Mode 7 will be shown automatically when loaded forks are lowered to ground Follow instruction for overload alert value input Weighing calibration fun...

Page 8: ... access buttons M and Arrow Up Make sure 0 number is inputed for digit 5 In our example for overload value of 4500 has only 4 digits As soon the last digit is inputed into the system Mode 7 will change to Mode 8 which is the normal operational mode Note If the lifted load is above preset overload value of 4500 the LCD display will Show actual overload value LED display showing the overload value w...

Page 9: ...oad weight total will be updated System will also show number of load weights taken Green Button Standard with SC2 series With LED display showing the latest accumulative load weight total by pressing green button system will reset Another accumulative load weight total function can be initiated Overload Alert Standard with SC1 and SC2 series The overload visual alert will be deactivated when load...