Overload Alert Value Input
When
SkidWeigh system weighing function calibration is completed,
loaded forks must be
lowered to ground.
The
Mode 7
digit automatically will be shown and will remain on LED display until overload alert
value is inputed into the system. With LED display showing
“Mode 7”
you have to enter the
overload alert value for that vehicle / application. In our example we will enter the overload alert
value of
4500
. Use paper clip to access buttons “M” and “Arrow Up”.Make sure
0
number is
inputed for digit 5.
(In our example for overload value of 4500 has only 4 digits)
As soon the last digit is inputed into the system
Mode 7
will change to
Mode 8
which is the
normal operational mode.
Note: If the lifted load is above preset overload value of 4500 the LCD display will
* Show actual overload value
* LED display showing the overload value will “flash”
* Overload value will stop “flashing” when loaded forks are lowered to the ground
Mode
Digit 5
Digit 4
Digit 3
Digit 2
Digit 1
7
0
7
0
7
5
7
4
7
0
Integrated Visual Data Technology Inc., 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7