4.4.6. - Tap support
4.4.7. - Min storage temp
4.4.8. - Tap support calibration
To ensure a constant temperature even with small amount of tap water, the circulation pump
can be used as support pump.
Not only does the circulation pump switch on under normal conditions, but also when a small
tapping occurs.
When a storage sensor is connected, tap support is only switched on when the Min storage
Temp is reached at the storage sensor.
Tap support is deactivated when the storage temperature drops below „Min storage temp“.
See „F3. Calibration“ on page 16.
4.10. - Comfort
If this function is activated, the heat exchanger will rinse for 5 seconds every 15 minutes,
so that hot water is available as soon as possible.
22
Settings
4.4.5. - Circulation period
Period where the circulation pump is enabled
Set the operation times of the circulation pump. 3 different periods can be set for every weekday,
which can also be copied to other days.
In periods not defi ned circulation is inactive.
The set periods are only used in the circulation mode “Periods”.