3. - Operating mode
In menu “3. Operating modes” the controller can either
be placed in automatic mode, switched off, or placed
in a manual operating mode.
The menu is closed by pressing “esc” or selecting “Exit
operating modes”.
3.1. - Automatic
Operating modes
3.2. - Manual
3.3. - Off
Automatic mode is the normal operating mode of the controller. Only automatic
mode provides proper controller function taking into account the current tempera-
tures and the parameters that have been set! After an interruption of the mains
voltage the controller automatically returns to the last operating mode selected!
Caution
When the operating mode “Off” is activated, all controller functions are switched
off. The measured temperatures are still displayed to provide an overview.
Caution
When operating mode “Manual” is activated, the current temperatures and the
selected parameters are no longer considered. There is a danger of scalding or
serious damage to the system. The operating mode “Manual” may only be used
by specialists for brief function tests or during commissioning! The relay and thus
the connected consumer are switched on and off by pressing a key, with no regard
to the current temperatures and the parameters which have been set. The mea-
sured temperatures are also shown to provide an overview and function control.
Danger