3VE490040NI – 01/20
Page 3
EN
VULCAN
A division of ITW Food Equipment Group LLC
P.O. Box 696
Louisville, KY 40201
The manufacturer disclaims any liability in the event that the above instructions are not followed.
The appliance should only be handled with suitable lifting equipment. Should the appliance need to be transported, this must be on its original
pallet and it must not be stacked on other appliances under any circumstances. If the appliance is to be moved without its pallet, it should be
carried and not pulled. Fig A1
LOCATION
ON A STAND
Secure the oven to the stand with four M6 x 50 bolts, there are threaded inserts under the oven. Fig 2.1A
Fix the stand to the floor. The legs must be fixed to the floor using the two stainless sockets provided with the stand. These should be fitted to
the rear legs. Fig 2.1B
Do not unscrew the feet more than 13mm (1/2"). Threads must not be visible.
ON A TABLE
With 4 Feet kit. Fig 2.3A-B
If necessary secure the oven to the support with four M10 x 50 bolts, there are threaded inserts under the oven
INSTRUCTION FOR HOT CONTAINERS
Maximal height for loading is 1600mm from the ground. A sticker is supplied with the instruction manual. Place the sticker on the Combi
oven at 1600mm from the ground. Fig 7Aʼ
Danger: For containers that are filled with liquid or food that liquefies during the cooking process, operators must be able to see the
contents of the container if it is inserted any higher.
CONNECTIONS
ELECTRICAL CONNECTION
The oven is equipped with a 1.77 m (70 inch) power cord and a plug NEMA L6-30P in single phase or NEMA L15-30P in three phase.
Connect the plug to the electrical network. Note: Never connect the oven to electrical network if the plug or the power cordon are damaged.
Remark : To avoid risk of disconnection, don't drag the power cord to the ground.
The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position.
All aspects of the installation should be in compliance with current local regulations (In France: NFC 15.100).
The appliance must be connected to the earth. Different electric appliances must also be cross bonded (all metallic structures at the same
potential) using the terminal provided for this purpose located next to the cable gland. Fig 5A
The manufacturer accepts no responsibility whatsoever if these instructions are not followed.
Do not operate any appliance with damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return
appliance to the nearest authorized service facility for examination, repair or adjustment.
For use on individual branch circuit only.
CAUTION : Disconnect from power supply before servicing.
To reduce the risk of electric shock, this equipment has a grounding type plug. This plug will only fit into a grounding type outlet. If the plug
does not fit into the outlet, contact a qualified electrician to install proper outlet. Do not change the plug in any way.
Voltage conversion from 208V 3~ to 208V 1~ or from 208V 3~ to 240V 1~
208V 3~
208V 1~ / 240V 1~
Cord and plug:
Replace by a model complying with the following
requirements
Six feet (1.8 m) long. Type SO, STO, SEO, SJO,
SJTO, SJEO, HSO, HSJO, or greater, with a
diameter of cord between 14.4 mm (9/16 inch) and
18 mm (11/16 inch) terminated by molded on
grounding type attachment plug, rated 30 A,
NEMA types (2 P + GND)
Page 8