PARAMETER ADJUSTMENT 

FREQUENCY OF MAINTENANCE AND LEVEL OF USE PER DAY 

- Go into the service screen 

- Press the “installation parameter” button 

- Enter the PIN code for the installer “INSB” 

- Validate “V”: when all the code has been entered and it is correct access the menu or start on the PIN number again. 

Frequency of maintenance, level of use per day 

- Enter the number of hours before the next service visit (1500 hours by default. Adjustable from 100 to 5000 hours. Allow at least one service per year.  

* Select the value to be modified 

* Adjust the setting using the coder 

- Enter the average hours per day that the unit is likely to operate. Adjustable from 1 to 24 hours. 

* Select the value to be modified 

* Adjust the value using the coder 

  

  

  

  

Frequency of maintenance 

Level of use per day 

  

  

  

  

  

  

  

  

Enter the contact name and phone number for servicing 

  

  

  

  

  

To validate this information press the return button 

  

WATER TREATMENT CAPACITY 

This only functions if there are 2 separate supplies to the oven. 

- Go into the service screen 

- Select “Client parameters” 

- Enter the PIN code “CHEF” Permanent password (upper or lowercase) 

- Validate “V”: when all the code has been entered and it is correct access the menu or start on the PIN number again. 

- Modify or check the water treatment capacity (in litres). Set to zero by default (if there is not a dedicated water treatment system for the oven). 

* Select the value to be modified 

* Adjust the setting using the coder 

Page 6

Summary of Contents for VMF061Ev2

Page 1: ...F51001 01 20 MINIJET FastPAD INSTALLATION MANUAL EN Combi Ovens 3VE490040NI Ed 01 2020 ...

Page 2: ...3VE490040NI 01 20 Page 1 VULCAN A division of ITW Food Equipment Group LLC P O Box 696 Louisville KY 40201 1 MANUTENTION A Fig 1A 2 HANDLING ON A STAND A Fig 2 1A B Fig 2 1B 4 x THM10 4 x 10 1 2 ...

Page 3: ...ision of ITW Food Equipment Group LLC P O Box 696 Louisville KY 40201 ON A TABLE A Fig 2 3A B Fig 2 3B 3 WATER CONNECTION A Fig 3A 4 DRAIN CONNECTION A Fig 4A 2 5 140 F 4 x 4 x Ø20 27 GHT adapter 35mm 1 minimum internal Ø20 27 GHT adapter ...

Page 4: ...01 20 Page 3 VULCAN A division of ITW Food Equipment Group LLC P O Box 696 Louisville KY 40201 5 ELECTRICAL CONNECTION A Fig 5A B Fig 5B 6 CLEANING PRODUCT CONNECTION A Fig 6A B Fig 6B Check data plate for Voltage ...

Page 5: ...3VE490040NI 01 20 Page 4 VULCAN A division of ITW Food Equipment Group LLC P O Box 696 Louisville KY 40201 7 GUIDELINES FOR HOT CONTAINERS A Fig 7A 1 x ...

Page 6: ...he bottom of the right hand side panel The double oven model is located in the same place Location of the data plate Dimension CODE Designation Energy U Lib KwE Imax A Weight Kg Depth Width High VMF061Ev2 Minijet FasPad 6 Levels GN1 1 Elec Electric 208 a c 5 205 24 00 74 00 35 20 29 VMF061Ev2 Minijet FasPad 6 Levels GN1 1 Elec Electric 208 3a c 5 205 14 90 74 00 35 20 29 VMF061Ev2 Minijet FasPad 6...

Page 7: ...he coder Enter the average hours per day that the unit is likely to operate Adjustable from 1 to 24 hours Select the value to be modified Adjust the value using the coder Frequency of maintenance Level of use per day Enter the contact name and phone number for servicing To validate this information press the return button WATER TREATMENT CAPACITY This only functions if there are 2 separate supplie...

Page 8: ...ther cooking appliances Unless specified otherwise the parts protected by the manufacturer or his authorized representative must not be handled by the installer The manufacturer certifies that the packaging meets the provision 94 62 CE relating to packaging and packaging waste of 20 12 94 and requests that the final installer or user observes the rules relating to the removal of the packaging recy...

Page 9: ...L15 30P in three phase Connect the plug to the electrical network Note Never connect the oven to electrical network if the plug or the power cordon are damaged Remark To avoid risk of disconnection don t drag the power cord to the ground The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position All aspects of the installation should be ...

Page 10: ...ia male thread 20 27 G 3 4 Fig 3A Attention Fit an approved double check valve to comply with local water regulations To check the quality of the water supply to your equipment 3 major factors need to be addressed see section Controlling water quality Parameter Level required Hardness 60 to 100 ppm 3 5 to 5 8 grains gal Chlorides Cl 150 mg l 150 ppm PH 6 5 to 9 Conductivity 50 µS cm Free chlorine ...

Page 11: ...etergent hose should not be altered in any way The detergent inlet hose is identified by a label and a coloured plug to ensure it is placed in the correct container Fig 6A B Never use descaling product in the automatic cleaning system This could seriously damage the ovens hydraulic circuits Note Refer to the Installation Recommendations section chapter when handling or using these chemicals if in ...

Page 12: ...Cl 150 mg l 150ppm Classical Water softener ion exchanger resin Reverse osmosis device or filters for total demineralization BRITA PURITY 1200 Clean or similar Set the filters integral by pass or use an external by pass PH 6 5 OK Check the water hardness 100 mg l CaCO3 5 8 gr gal Reverse osmosis device or filters for total demineralization BRITA PURITY 1200 Clean or similar No OR Don t connect the...

Reviews: