208V 3~
208V 1~ / 240V 1~
Heating elements connection
208V
240V
Main transformer
Data plate:
Replace the two data plates by the models in the
good configuration (Stick them on the previous
model)
On the data plate, the configurations are
differentiated in item “Model” by the two last digits.
V2MF061E-66
208V 1~
V2MF061E-76
240V 1~
V2MF061E-96
240V 3~
WATER CONNECTION
- Maximum 104°F cold potable water
- Maximum 104°F cold softened water
- Nature: 168 µm (90 Mesh) filter integral with the oven
- Minimum pressure: 1.5 bars, maxi: 6 bars.
- Provide a shut-off valve in the vicinity.
- Any deterioration by lime deposit (cavity walls, heating elements, fan, hydraulic…) will not be guaranteed by the builder.
- Final connection at the rear via male thread 20/27 (G 3/4") Fig 3A
Attention: Fit an approved double check valve to comply with local water regulations.
- To check the quality of the water supply to your equipment, 3 major factors need to be addressed (see section « Controlling water quality »)
Parameter
Level required
Hardness
60 to 100 ppm (3.5 to 5.8 grains/gal)
Chlorides (Cl
-
)
≤
150 mg/l (150 ppm)
PH
6.5 to 9
Conductivity
≥
50 µS / cm
Free chlorine (Cl
2
)
≤
0.2 mg / l (0.2 ppm)
Water consumption : Indication of maximum water consumption for adjustment of a separate softener.
Maximum water consumption
Liters / hour
50 (13.2 gal/h)
DRAIN CONNECTION
The water discharged could be condensate and at very high temperature (98°C). Only use materials suitable for these temperatures.
The oven is equipped with a trap which connects the appliance directly to the external drainage system to comply with pollution control
standards.
It is vital that there is a trap between the unit and the drainage system to prevent back odours. Fig 4A
One in internal part
One in external part