Phoenix Ionizing Blower

5200632 Rev. E

5. OPERATION

Before energizing this equipment:
1.  Ensure that the unit is properly grounded.
2.  Ensure that all static control devices have been properly located, positioned and 

installed.

After the above checks have been performed, simply turn the fan speed control knob 

from the OFF position to the desired airflow setting.  Use the highest airspeed that the 

application allows.  With the fan speed set to maximum, the Phoenix will neutralize static 

charges at a distance of ten feet.  As the fan speed is decreased, neutralization range will 

also decrease.

NOTE

 – Do not allow dust, dirt or debris to block or obstruct the airflow inlets 

or outlets.

CAUTION – Electrical Shock Hazard

Always disconnect power supply before cleaning static neutralizing equipment. 

Avoid touching static neutralizing points when power supply is energized.

Summary of Contents for SIMCO-ION Phoenix

Page 1: ...Phoenix Ionizing Blower 5200632 Rev E Phoenix Ionizing Blower INSTALLATION AND OPERATING INSTRUCTIONS ...

Page 2: ...ix Ionizing Air Blower 120 VAC 3 Phoenix Ionizing Air Blower 230 VAC 4 4 INSTALLATION 5 Positioning and Mechanical Requirements 5 Electrical Connections 5 5 OPERATION 6 6 TROUBLESHOOTING 7 Operational Check 7 Ion Balance Adjustment 7 7 MAINTENANCE 8 Front Screen 8 Ionizing Emitter Points 8 Air Intake Filters 8 8 REPLACEMENT PARTS ADDITIONAL ITEMS 9 9 WARRANTY 9 ...

Page 3: ...instruction manual before installing or operating equipment 2 Only qualified service personnel are to perform installation and repairs 3 All equipment must be properly grounded including the machine frame to which the equipment is mounted 4 Do not operate device in excess of specifications NOTE Do not attempt to operate at voltages other than those specified NOTE Do not allow dust dirt or debris t...

Page 4: ...a bench stand to aid in directing the ionized air stream An optional floor stand with wheels is also available Receipt of Equipment 1 Carefully remove the equipment from its carton 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred the local carrier should be notified at once A report should be forwarded to Simco Ion 2257 North Penn Road Hatfield PA 194...

Page 5: ...e Air Speed Characteristics 2 000 FPM at 1 ft fan speed high 1 250 FPM at 2 ft fan speed high 800 FPM at 4 ft fan speed high Noise Level 68 dB at high fan speed 2 ft from blower Ionization Indicator Status lamp illuminates when high voltage is present at the emitter points Short Circuit Current 0 175 mA max emitter point to ground Typical Discharge Times 0 5 sec at 1 ft 5000V to 500V 1 0 sec at 2 ...

Page 6: ...cs 2 000 FPM at 1 ft fan speed high 1 250 FPM at 2 ft fan speed high 800 FPM at 4 ft fan speed high Noise Level 68 dB at high fan speed 2 from blower Ionization Indicator Status lamp illuminates when high voltage is present at the emitter points Short Circuit Current 0 175 mA max emitter point to ground Typical Discharge Times 0 5 sec at 1 ft 5000V to 500V 1 0 sec at 2 ft 5000V to 500V 2 0 sec at ...

Page 7: ...bench stand It can also be wall or ceiling mounted using the tapped mounting holes in the base of the stand The Phoenix may also be placed on an OPTIONAL vertically adjustable floor stand that can be moved and positioned as required Electrical Connections 1 The Phoenix requires 120 VAC 60 Hz or 230 VAC 50 60 Hz for operation Depending on the model terminate line cord with plug if required Connect ...

Page 8: ...to the desired airflow setting Use the highest airspeed that the application allows With the fan speed set to maximum the Phoenix will neutralize static charges at a distance of ten feet As the fan speed is decreased neutralization range will also decrease NOTE Do not allow dust dirt or debris to block or obstruct the airflow inlets or outlets CAUTION Electrical Shock Hazard Always disconnect powe...

Page 9: ...or your local Simco Ion Representative NOTE Never use a spark test to check operation The balancing circuit design of the Phoenix makes the spark test inconclusive and can permanently damage the circuit Ion Balance Adjustment 1 An electronic balancing circuit in the blower controls the output ration of negative to positive ions The circuit is preset at the factory and normally requires no further ...

Page 10: ...ill reduce the effectiveness of the blower The ionization points must be cleaned periodically to prevent deposits from accumulating 2 Simply turn OFF the unit and slide the built in Point Cleaner located on the front face of the blower from one side to the other and back again 3 Frequency of cleaning should be at least once monthly or as determined by inspections based on operating conditions Air ...

Page 11: ...d PA 19440 transportation prepaid and insured for its replacement cost Prior to returning any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessness...

Page 12: ...Phoenix Ionizing Blower 5200632 Rev E Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2015 Simco Ion Printed in the U S A ...