![ITW SIMCO-ION Phoenix Installation And Operating Instructions Manual Download Page 5](http://html.mh-extra.com/html/itw/simco-ion-phoenix/simco-ion-phoenix_installation-and-operating-instructions-manual_2096664005.webp)
3
Phoenix Ionizing Blower
5200632 Rev. E
3. SPECIFICATIONS
Phoenix Ionizing Air Blower (120 VAC)
Line Voltage
120 VAC, 60 Hz
Current Draw
2.0A (fan speed high)
Operating Temperature
32-100˚F max (0-38˚C)
Operating Humidity
70% RH max, no dewing permissible
Dimensions
16-3/8L x 13-1/4W x 9-3/4H in
Weight
16.1 lb
Blower Output
110-300 CFM (adjustable)
Air Speed Characteristics
2,000 FPM at 1 ft (fan speed high)
1,250 FPM at 2 ft (fan speed high)
800 FPM at 4 ft (fan speed high)
Noise Level
68 dB at high fan speed (2 ft from blower)
Ionization Indicator
Status lamp illuminates when high voltage is present at the emitter
points
Short Circuit Current
0.175 mA max (emitter-point to ground)
Typical Discharge Times
0.5 sec at 1 ft (5000V to 500V)
1.0 sec at 2 ft (5000V to 500V)
2.0 sec at 3 ft (5000V to 500V)
2.5 sec at 4 ft (5000V to 500V)
3.5 sec at 5 ft (5000V to 500V)
12.0 sec at 10 ft (5000V to 500V)