8
Phoenix Ionizing Blower
5200632 Rev. E
7. MAINTENANCE
NOTE
– Never use hard or sharp objects to scrape ionization points.
CAUTION – Electrical Shock Hazard
Turn OFF power before performing any maintenance tasks on the Phoenix.
Front Screen
1. The screen at the air outlet on the front panel should remain clean to prevent
restriction of airflow.
2. Turn OFF the unit and clean the outlet screen with a soft brush and/or vacuum
cleaner.
Ionizing Emitter Points
1. Dust or dirt around the ionization points will reduce the effectiveness of the
blower. The ionization points must be cleaned periodically to prevent deposits from
accumulating.
2. Simply turn OFF the unit and slide the built-in Point Cleaner (located on the front
face of the blower) from one side to the other and back again.
3. Frequency of cleaning should be at least once monthly, or as determined by
inspections based on operating conditions.
Air Intake Filters
1. Filter cleaning or replacement frequency depends upon the cleanliness of the
operating environment. Inspect filters weekly, replacing or cleaning as required.
2. Simply turn OFF the unit, slide dirty filters out from under the three fixed retaining
clips, and replace with clean filters.