Last warning
Date and timestamp indicating when the last
Warning was registered.
Last alarm
Date and timestamp indicating when the last
Alarm was registered.
Data logging
Off
The data logging (measured values) for the
Device is disabled.
On
The data logging (measured values) for the
Device is enabled.
Autorun
No
After giving a Global Run, the Device will not go
into Running mode. The Device can only be set
to Running via a Device Run.
Yes
After giving a Global Run, the Device will go into
Running mode.
Graphic refresh time
0.5 s
Time interval with which the speed at which the
graphic screen is refreshed is also set. See also
Article 6.11.2.
1 s
5 s
10 s
1 min
10 min
Remote on/off source
Continuous
In Running mode, charging and discharging bars
provide continuous high voltage. With a sensor rod,
the measuring elements will always be active.
Input
In Running mode, the charging and discharging
bars only provide high voltage when the external
Remote On/Off input is active.
Fieldbus (*)
In Running mode, the charging and discharging
bars only provide high voltage when the Fieldbus
Remote On/Off control is active.
Firmware version
Identification of the current firmware version of
the Device.
Device serial number
Device serial number.
(*): This parameter is only available if the Fieldbus versions of the Backplane are used.