4
IQ Power HL Sensor
5201252 Rev. A
3. SPECIFICATIONS
Input Power
24 VDC, 30 mA nominal
Input Connection
via (user supplied) Intrinsic Safety Barriers (ref. Control Drawing
5150010)
Input Cable Lengths
30 ft (9.1m)
Input Purge Gas
(for minimizing dust, dirt and contamination in probe aperture
only)
1 to 2.5 psi (7 to 17 kPa) nominal operating pressure
5 psi (35 kPa) max operating pressure
0.14 scfm (4 NL/min) per sensor at 1 psi (5 kPA)
0.22 scfm (6 NL/min) per sensor at 2.5 psi (20 kPa)
Clean, dry, oil-free compressed air or nitrogen
Gas Input Connection
¼” OD Tubing, Quick Disconnect
Operating Temperature
40˚C [104˚F] max
Operating Humidity
70% RH max, no dewing permissible
Operating Distance*/Voltage
2” (50 mm) 20 kV max
3” (75 mm) 25 kV max
4” (100 mm) 30 kV max (factory default setting)
6” (150 mm) 40 kV max
8” (200 mm) 50 kV max
10” (250 mm) 60 kV max
Dimensions
260L x 32.5W x 44.5H mm [10.25”L x 1.28”H x 1.75”H]
Weight
0.68 kg [1.5 lb]
Enclosure
Stainless Steel and Conductive Polyamide
Mounting Hardware
Zinc plated metal perforated strip, stainless steel hardware
*Note: the operating distance set for sensor in control station must be the same as
mounting distance sensor to web. This is critical for accurate calibration.