14
5100577 Rev L
CONVEYOSTAT IN-LINE IONIZER
NOTE
– Device power input is protected by an internal fuse identified
as F1 that is replaceable only by qualified service personnel. Use
cartridge-type slow blow 0.25 x 1.25” fuses rated 250V, 5A only (such
as Little Fuse 0313005.HXP or equivalent).
Conveyostat with Dual Phase+
PROBLEM
CAUSE
SOLUTION
Power indicator
NOT illuminated
Power not on at power supply
Turn on Power switch on power supply
Poor electrical connections
Check input power connections and voltage
Warning indicator
illuminated
Process material fouling static bar ion
emitters
Remove process material from static bar
Dirt build-up on ion emitters or conductive
contamination on face of bar
Clean ion emitters and static bar. See
Maintenance section for details
Fault indicator
illuminated
Static bar shorted to grounded metal
Clear debris shorting static bar to grounded
metal
Damage to high voltage connector
Replace high voltage connector
Damage to high voltage cable
Replace defective cable
High voltage transformer inside power
supply faulty
Replace high voltage transformer