OPERATION 

WARNING:

  THE STOCKPOT RANGE AND ITS PARTS ARE HOT. BE CAREFUL WHEN 

OPERATING, CLEANING OR SERVICING THE STOCKPOT RANGE. 

CONTROLS  

The burner is in two sections, controlled by two heavy duty infinite control valves. The 
center “Star” section (Fig. 2) is on separate burner with an input of 55,000 BTU/hr. It is 
controlled by the right burner valve knob. The outer circle of the burner (Fig. 2) is the 
other separate 55,000 BTU/hr input burner, controlled by the left burner valve knob. 

These two separate burners provide heat flexibility. With one burner off and the second 
burner set low, up to both burners full on, you can move from low simmer on up to 
110,000 BTU/hr input. 

 

Fig. 1 

Fig 2. 

 

LIGHTING INSTRUCTIONS 

  1.  Turn all burner valves to OFF position and wait 5 minutes. 

  2.  Turn gas shutoff valve ON.   

  3.  Light standing pilot with a lit taper. Adjust pilot to ¼” high flame, if necessary, by 

turning pilot valve adjusting screw (see Fig. 1) counterclockwise to increase or 
clockwise to decrease flame. 

  4.  Turn burner valve to ON position. 

  5.  If pilot does not light, turn main gas supply OFF and repeat steps 1 through 4. 

 

TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS 

For complete shutdown: Turn the main gas supply valve OFF. 

 

INNER 

BURNER 

OUTER 

BURNER 

PILOT VALVE 

SCREW 

Summary of Contents for ML-052822

Page 1: ...TAIN THIS MANUAL FOR FUTURE USE FORM F 36951 04 07 INSTALLATION OPERATION MANUAL FOR Stockpot Range MODELS MLS VSP100 ML 052822 VSP200 ML 052823 VSP200F ML 769292 www vulcanhart com MODELS MLS WSPR1 ML 760600 WSPR2 ML 760601 WSPR2F ML 769292 www wolfrange com VSP100 WSPR2F ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...the clearance dimensions see below agree with the specifications on the rating plate which is located at the back of the stockpot LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the stockpot adjacent to open burners or fryers Sufficient air should be allowed to enter the room to compensate for ...

Page 4: ...tion Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column W C for natural gas and 10 W ...

Page 5: ... A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate gas supply is necessary Un...

Page 6: ...xibility With one burner off and the second burner set low up to both burners full on you can move from low simmer on up to 110 000 BTU hr input Fig 1 Fig 2 LIGHTING INSTRUCTIONS 1 Turn all burner valves to OFF position and wait 5 minutes 2 Turn gas shutoff valve ON 3 Light standing pilot with a lit taper Adjust pilot to high flame if necessary by turning pilot valve adjusting screw see Fig 1 coun...

Page 7: ... STOCKPOT RANGE AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING SERVICE Contact your local Service Agency for any repairs or adjustments needed on this equipment TROUBLESHOOTING PROBLEM POSSIBLE CAUSES Pilot Outage 1 Pilot flame too low 2 Restriction in pilot orifice 3 Restriction in pilot valve Improper burner combustion Improper ventilation Poor Ignition 1 Insufficient gas in...

Reviews: