background image

 

3

 - 

INSTALLATION, OPERATION AND CARE OF 

STOCKPOT RANGE 

 

GENERAL 

 
Stockpot ranges are designed for commercial use only and feature fast, efficient gas 
heat.  Each burner is controlled by an adjustable gas valve. Heavy-duty, cast iron top 
grate(s) are easily removed for cleaning when cool. A grease drawer is provided to collect 
fat run-off; it opens to the front for inspection or drain-off. 
 

Model 

Number of Burners 

BTU/hr Input Rating 

VSP100, WSPR1 

110,000 

VSP200, WSPR2 

220,000 

VSP200F, WSPR2F 4 

220,000 

 

INSTALLATION 

UNPACKING 
 

Immediately after unpacking, check for possible shipping damage.  If the stockpot is 
found to be damaged, save the packaging material and contact the carrier within 15 days 
of delivery. 
 
Before installing, verify that the type of gas (natural or propane) and the clearance 
dimensions (see below) agree with the specifications on the rating plate which is located 
at the back of the stockpot. 

 

LOCATION 

The installation location must be kept free and clear of combustibles.  Do not obstruct the 
flow of combustion and ventilation air. DO NOT install the stockpot adjacent to open 
burners or fryers. 

Sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilating system and for combustion of the gas burners.  Do not 
obstruct the air flow into and around the appliance.  Do not obstruct the flow of flue gases 
through and above the stockpot top grate.  Position the stockpot in its final location.  
Check that there are sufficient clearances to service the stockpot and to make the 
required gas supply connection(s).  Provide 24" clearance at the front for cleaning, 
maintenance, service and proper operation.   

Minimum Clearance 

Combustible Construction 

Non-Combustible Construction 

Rear 24” 

4” 

Sides 18” 

0” 

 

Summary of Contents for ML-052822

Page 1: ...TAIN THIS MANUAL FOR FUTURE USE FORM F 36951 04 07 INSTALLATION OPERATION MANUAL FOR Stockpot Range MODELS MLS VSP100 ML 052822 VSP200 ML 052823 VSP200F ML 769292 www vulcanhart com MODELS MLS WSPR1 ML 760600 WSPR2 ML 760601 WSPR2F ML 769292 www wolfrange com VSP100 WSPR2F ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...the clearance dimensions see below agree with the specifications on the rating plate which is located at the back of the stockpot LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the stockpot adjacent to open burners or fryers Sufficient air should be allowed to enter the room to compensate for ...

Page 4: ...tion Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5 Water Column W C for natural gas and 10 W ...

Page 5: ... A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate gas supply is necessary Un...

Page 6: ...xibility With one burner off and the second burner set low up to both burners full on you can move from low simmer on up to 110 000 BTU hr input Fig 1 Fig 2 LIGHTING INSTRUCTIONS 1 Turn all burner valves to OFF position and wait 5 minutes 2 Turn gas shutoff valve ON 3 Light standing pilot with a lit taper Adjust pilot to high flame if necessary by turning pilot valve adjusting screw see Fig 1 coun...

Page 7: ... STOCKPOT RANGE AND ITS PARTS ARE HOT USE CARE WHEN OPERATING CLEANING OR SERVICING SERVICE Contact your local Service Agency for any repairs or adjustments needed on this equipment TROUBLESHOOTING PROBLEM POSSIBLE CAUSES Pilot Outage 1 Pilot flame too low 2 Restriction in pilot orifice 3 Restriction in pilot valve Improper burner combustion Improper ventilation Poor Ignition 1 Insufficient gas in...